An accurate and transferable protocol for reproducible quantification of organic pollutants in human serum using direct isotope dilution mass spectrometry

文献情報

出版日 2014-08-05
DOI 10.1039/C4AN00851K
インパクトファクター 4.616
著者

Andrew J. Boggess, G. M. Mizanur Rahman, Matt Pamukcu, Scott Faber, H. M. Skip Kingston


原文を見る

要旨

A robust method has been developed for easy transfer between analytical laboratories to obtain highly accurate and reproducible quantification of persistent organic pollutants (POPs) in micro-volumes of serum. This method is suited for analysts researching the impact of environmental exposure on human health. When performed by highly trained analysts, existing methods can produce high quality data; however, complex sample preparation steps often cannot be consistently replicated by laboratories, leading to variance in extraction recovery and quantitation. By combining stir-bar sorptive extraction (SBSE) with direct isotope dilution (D-ID) mass spectrometry quantification, a new analytical method was developed. The D-ID quantification significantly improved accuracy, corrected sample-to-sample irreproducibility, and reduced sample preparation time. Independent production of statistically identical data then confirmed transfer of the validated operating protocol to an off-site laboratory with different instrument models. SBSE performance was compared with industry-accepted extraction techniques. D-ID quantification was compared with peer-reviewed relative isotopic response factor (RF) quantification methods. Holding other variables constant, D-ID improved accuracy by 250% and precision by 300% compared with RF; SBSE improved accuracy by 37% compared to industry-accepted extraction methods. Limits of quantification of the analytes ranged from 60 pg g−1 to 1 μg g−1. Protocol transfer exhibited <7% mean between-laboratory error and <2% mean within-laboratory RSD. These results indicate that a transferable method has been developed for academic, government, commercial, and clinical laboratories seeking to maximize throughput and improve quantitative validity. This validated method was applied in a recent clinical study to assess non-communicable disease in children in Pennsylvania, USA.

関連文献

Complete tetraglycosylation of a calix[4]arene by a chemo-enzymatic approach

Silvia Bernardi, Dong Yi, Ning He, Alessandro Casnati, Wolf-Dieter Fessner, Francesco Sansone

2017-11-15 Paper

DOI: 10.1039/C7OB02448G

Photoinduced triiodide-mediated [3 + 2] cycloaddition of N-tosyl aziridines and alkenes

Yuanbo Li, Fan Chen, Shengqing Zhu, Lingling Chu

2021-03-02 Research Article

DOI: 10.1039/D1QO00102G

Automated glycan assembly of galactosylated xyloglucan oligosaccharides and their recognition by plant cell wall glycan-directed antibodies

Colin Ruprecht, Peter J. Smith, Michael G. Hahn, Breeanna R. Urbanowicz

2017-11-21 Communication

DOI: 10.1039/C7OB02605F

Structural characterisation of natural products by means of quantum chemical calculations of NMR parameters: new insights

Fabio L. P. Costa, Ana C. F. de Albuquerque, Rodolfo G. Fiorot, Luciano M. Lião, Lucas H. Martorano, Gunar V. S. Mota, Alessandra L. Valverde, José W. M. Carneiro, Fernando M. dos Santos Junior

2021-02-22 Review Article

DOI: 10.1039/D1QO00034A

Photo-induced weak base-catalyzed synthesis of α-haloboronates from vinylboronates and polyfluoroalkyl halides

Tongchang Fang, Jian Qiu, Kai Yang

2021-02-26 Research Article

DOI: 10.1039/D1QO00169H

Highly regioselective gold-catalyzed formal hydration of propargylic gem-difluorides

Jean-Denys Hamel, Tatsuru Hayashi, Mélissa Cloutier, Paul R. Savoie, Olivier Thibeault, Meggan Beaudoin, Jean-François Paquin

2017-11-13 Paper

DOI: 10.1039/C7OB02406A

Back cover

2021-06-01 Cover

DOI: 10.1039/D1QO90049H

こちらもおすすめ

化合物よくある質問

2-氟-4-イオドベンzo酸エチルエステルを取り扱う際の実験室安全事項は何ですか?

2-氟-4-イオドベンzo酸エチルエステルは有機溶媒を用いた反応であり、ドラフトチャンバーでの操作が必要です。漏洩時にはSDS参照の安全措置を講じ、PPE(防護...

205750-82-9Benzoic acid, 2-fluo...
化合物よくある質問

血根碱の主な用途は何ですか?

血根碱は主に医薬分野で利用され、抗炎症や抗がん剤としての潜在的な効果が研究されています。また、化学研究や薬物開発において、新しい薬剤設計の参考となる化合物として...

2447-54-313-Methyl[1,3]benzod...
化合物よくある質問

Methyl 3-methoxythiophene-2-carboxylateの主な用途は何ですか?

Methyl 3-メトキシスチフェン-2-カルボン酸メチルエステルは、薬品合成、染料製造、以及合成中間体としての用途が広がっています。

62353-75-7Methyl 3-methoxythio...
化合物よくある質問

丹磺酰-L-亮氨酸はどのように保存すればよいですか?

丹磺酰-L-亮氨酸は乾燥した場所で、直射日光から保護し、低温(室温以下)で保存してください。密閉容器に入れて保管することをおすすめします。

1100-22-7N-{[5-(Dimethylamino...
化合物よくある質問

5-(苄氧基)ピラミジン-4-アミンの代替品はありますか?

5-(苄氧基)ピラミジン-4-アミンの代替品として、6-メトキシピラミジンや5-フェニルピラミジンなどが挙げられます。これらの化合物は、5-(苄氧基)ピラミジン...

92289-50-45-benzyloxypyrimidin...
化合物よくある質問

8-ヒドロキシノルデコペントアセートの物理化学的性質は何ですか?

8-ヒドロキシノルデコペントアセートはCAS番号84807-87-4の化合物で、分子量は750.02 uです。これは油溶性で、水に溶けにくい特徴があります。反応...

84807-87-4(5Z,8Z,11Z,13E,15S)-...
化合物よくある質問

tert-ブチル(エス)-1-ヒドロキシペンタ-4-エン-2-イルカルバamateの主な用途は何ですか?

tert-ブチル(エス)-1-ヒドロキシペンタ-4-エン-2-イルカルバamateは主に医薬品の合成材料や分析化学の試薬として使用されます。

116613-81-12-Methyl-2-propanyl ...
化合物よくある質問

ブコール-L-2-フローヨルブリンについて適切な法規ガイドラインは何ですか?

ブコール-L-2-フローヨルブリン(CAS番号: 1196107-73-9)は、GHS(グローバルハザードアサessmentシステム)に基づく危害分類と表示が求...

1196107-73-92-Bromo-13,13-dimeth...
化合物よくある質問

6-ブロモ-N-環丙基-2-ピリジニニメタンの市場動向や研究トレンドはどうですか

6-ブロモ-N-環丙基-2-ピリジニニメタンは、薬理学研究や合成化学に使用される化合物であり、特に抗ウイルス薬や抗がん薬の開発に注目されています。市場では、薬物...

959237-20-86-Bromo-N-cyclopropy...
化合物よくある質問

RS-AMPÀはどのように保存すればよいですか?

RS-AMPÀは、遮光容器に保存し、室温(15〜25℃)で保管することが推奨されます。高湿や熱は物質を劣化させるため、湿度は50%以下に保つことが重要です。また...

74341-63-2(RS)-AMPA

掲載誌

Analyst

Analyst
CiteScore: 7.8
自己引用率: 5.6%
年間論文数: 653

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.

おすすめ化合物

おすすめサプライヤー

免責事項
このページに表示される学術雑誌情報は、参考および研究目的のみを目的としています。当社は雑誌出版社とは提携しておらず、投稿の取り扱いも行っておりません。出版に関するお問い合わせは、各雑誌出版社に直接ご連絡ください。
表示されている情報に誤りがある場合は、support@chemtradehub.com までご連絡ください。迅速に確認し、対応いたします。