An enhanced fluorescent sensor system based on molecularly imprinted polymer chips with silver nanoparticles for highly-sensitive zearalenone analysis

文献情報

出版日 2023-05-11
DOI 10.1039/D2AN01991D
インパクトファクター 4.616
著者

Daria Yarynka, Volodymyr Chegel, Elena Piletska, Sergey Piletsky, Larysa Dubey, Igor Dubey, Roman Nikolaiev, Oleksandr Brovko, Tetyana Sergeyeva


原文を見る

要旨

A novel enhanced fluorescent sensor system for zearalenone (ZON) determination in flour samples is presented. The ZON-selective molecularly imprinted polymer (MIP) films were developed with a computational modelling method and synthesised with cyclododecyl-2,4-dihydroxybenzoate as a “dummy” template and ethylene glycol methacrylate phosphate as a functional monomer acted as the selective recognition elements for ZON fluorescence detection. Spherical silver nanoparticles (AgNPs) were embedded in the MIP films’ structure to enhance the sensor sensitivity. The imprinted films showed a high ZON recognition ability compared to non-imprinted films. Various factors that affected the measurement of the analysed sample were investigated and optimised. Embedding the AgNPs in the MIP films’ structure led to an enhanced sensitivity (up to a 200-fold decrease of LOD) compared to unmodified MIP films. This fluorescent sensor system provided ZON analysis with high sensitivity, specificity, and a wider linear dynamic range of 5 ng mL−1 to 25 μg mL−1. An enhanced fluorescent sensor system based on MIP chips with embedded AgNPs could detect trace amounts of ZON in foods and feedstuffs with high sensitivity and selectivity.

関連文献

Smartphone-based point-of-care testing of salivary α-amylase for personal psychological measurement

Lin Zhang, Wentao Yang, Yuankui Yang, Hong Liu, Zhongze Gu

2015-09-23 Paper

DOI: 10.1039/C5AN01664A

Cellular discrimination using in vitro Raman micro spectroscopy: the role of the nucleolus

Z. Farhane, F. Bonnier, A. Casey, A. Maguire, L. O'Neill, H. J. Byrne

2015-07-20 Paper

DOI: 10.1039/C5AN01157D

Contribution of Raman spectroscopy in nephrology: a candidate technique to detect hydroxyethyl starch of third generation in osmotic renal lesions

T. T. Nguyen, A. Wynckel, M. Fere, L. Van-Gulick, V. Untereiner, P. Birembaut

2015-09-10 Paper

DOI: 10.1039/C5AN00821B

Enhancing biological analyses with three dimensional field asymmetric ion mobility, low field drift tube ion mobility and mass spectrometry (μFAIMS/IMS-MS) separations

Xing Zhang, Yehia M. Ibrahim, Tsung-Chi Chen, Jennifer E. Kyle, Randolph V. Norheim, Matthew E. Monroe, Richard D. Smith, Erin S. Baker

2015-06-30 Paper

DOI: 10.1039/C5AN00897B

Label-free detection of missense mutations and methylation differences in the p53 gene using optically diffracting hydrogels

Kelsey I. MacConaghy, Duncan M. Chadly, Mark P. Stoykovich, Joel L. Kaar

2015-08-06 Paper

DOI: 10.1039/C5AN01191D

Sub-cellular spectrochemical imaging of isolated human corneal cells employing synchrotron radiation-based Fourier-transform infrared microspectroscopy

Imran I. Patel, Júlio Trevisan, Takahiro Nakamura, Carol J. Hirschmugl, Nigel J. Fullwood, Francis L. Martin

2012-11-01 Paper

DOI: 10.1039/C2AN36197C

Collision-energy resolved ion mobility characterization of isomeric mixtures

Michael E. Pettit, Brett Harper, Matthew R. Brantley, Touradj Solouki

2015-07-15 Paper

DOI: 10.1039/C5AN00940E

Highly sensitive ligand-binding assays in pre-clinical and clinical applications: immuno-PCR and other emerging techniques

Mark Spengler, Michael Adler, Christof M. Niemeyer

2015-07-21 Critical Review

DOI: 10.1039/C5AN00822K

Investigating carbohydrate isomers by IMS-CID-IMS-MS: precursor and fragment ion cross-sections

M. M. Gaye, R. Kurulugama, D. E. Clemmer

2015-08-07 Paper

DOI: 10.1039/C5AN00840A

こちらもおすすめ

化合物よくある質問

除水剤ALT-201は安全ですか?

除水剤ALT-201は一般的に安全ですが、避けるべきは皮膚や目への接触です。適切な防護具を着用し、安全基準を守ることが重要です。

28770-01-62-(2-Isopropyl-1,3-o...
化合物よくある質問

「邻羟基阿托伐他汀内酯标准品」に適用される法規ガイドelinesは何ですか?

CAS番号163217-74-1の「邻羟基阿托伐他汀内酯标准品」は、GHS分類では危険物に分類されず、主にREACH規則とFDA/EPAの管理対象となります。R...

163217-74-1ortho-Hydroxy Atorva...
化合物よくある質問

メチル(3R)-3-アミノ-2,3-ジヒドロ-1-ベンゾファンラニン-5-カルボイル酸塩塩酸塩の主な用途は何ですか?

メチル(3R)-3-アミノ-2,3-ジヒドロ-1-ベンゾファンラニン-5-カルボイル酸塩塩酸塩は、医薬品や合成化学の研究に広く用いられます。また、特定の薬物の前...

2241594-15-8Methyl (3R)-3-amino-...
化合物よくある質問

トランス-4-メチルピロリジン-3-オール塩酸塩はどのように合成されますか?

トランス-4-メチルピロリジン-3-オール塩酸塩は、4-メチルピロリジンの塩酸塩化によって合成されます。一般的な合成方法では、4-メチルピロリジンを塩酸に加えて...

265108-42-7trans-4-Methylpyrrol...
化合物よくある質問

硫雜環丁烷-1,1-二氧化物は安全ですか?

硫雜環丁烷-1,1-二氧化物は安全ではありません。毒性は報告されていませんが、高温下で分解し、可燃性があるため、高圧ガスは注意が必要です。密閉した容器で保管し、...

5687-92-3Thietane 1,1-dioxide
化合物よくある質問

ブラエリリンの主な用途は何ですか?

ブラエリリンは主に医薬品製造における薬物アドベリンの合成材料として使用されます。また、研究用途や化学合成材料としても広く利用されています。

6054-10-02H, 8H-Benzo[1,2-b
化合物よくある質問

9-ヒドロキシエリプチシネ塩酸塩はどのように合成されますか?

9-ヒドロキシエリプチシネ塩酸塩は、エリプチシネから塩酸を添加することで合成されます。選択性は高いですが、収率は約70%です。

52238-35-49-Hydroxyellipticine...
化合物よくある質問

5-塩素-2-(メチルアミノ)フェニル-(2-塩素フェニル)メタン酮の物理化学的性質は何ですか?

5-塩素-2-(メチルアミノ)フェニル-(2-塩素フェニル)メタン酮のCAS番号は5621-86-3です。この化合物は白色の結晶性粉末で、分子量は415.03で...

5621-86-3[5-Chloro-2-(methyla...
化合物よくある質問

1-[2-(4-甲氧基-苯氧基)-乙基]-哌嗪はどのように保存すればよいですか?

1-[2-(4-甲氧基-苯氧基)-乙基]-哌嗪は、直射日光を避けて暗所に、室温(15-25℃)で保管し、密閉容器に入れることで安定性を保つことができます。

117132-44-21-[2-(4-Methoxy-phen...
化合物よくある質問

2-[3-(4-甲氧基フェニル)プロピル]-4,4,5,5-四メチル-1,3,2-ドイボロロールアンの主な用途は何ですか?

2-[3-(4-甲氧基フェニル)プロピル]-4,4,5,5-四メチル-1,3,2-ドイボロロールアンは、医薬品の合成、有機合成化学、および新材料の研究で使用され...

1073371-72-82-[3-(4-Methoxypheny...

掲載誌

Analyst

Analyst
CiteScore: 7.8
自己引用率: 5.6%
年間論文数: 653

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.

おすすめサプライヤー

免責事項
このページに表示される学術雑誌情報は、参考および研究目的のみを目的としています。当社は雑誌出版社とは提携しておらず、投稿の取り扱いも行っておりません。出版に関するお問い合わせは、各雑誌出版社に直接ご連絡ください。
表示されている情報に誤りがある場合は、support@chemtradehub.com までご連絡ください。迅速に確認し、対応いたします。