Design optimization, sensitivity analysis and operational comparison of a duplex helical elliptical tube metal hydride reactor
文献情報
Di Wang, Shanshan Li, Zhiru Liu, Fusheng Yang, Zhen Wu, Zaoxiao Zhang, Jinqiao Wu, Lei Shi, Jie Yuan
Due to the strong exothermic/endothermic effect during the H2 absorption/desorption process, the design of metal hydride reactors has become a hot research topic to improve the rate of hydrogenation/dehydrogenation. Herein, based on bionic optimization and the constructal theory, a novel duplex helical elliptical tube reactor (DHER) is proposed for enhancing the heat transfer and reaction performances of metal hydride reactors. DHER displayed outstanding performances among 5 types of reactors, and the maximal temperature difference could be reduced by 5.1 K/5.6 K during the H2 absorption/desorption. The parameters of DHER were designed and optimized with the spiral diameter (Dc) = 10 mm, elliptical major axis (A) = 4 mm, elliptical minor axis (B) = 2 mm, pitch (Pt) = 13 mm, tilt angle (α) = 45°, and installation angle (β) = 180°. The sensitivity analysis for DHER is investigated, and the sequential effects of the structural parameters on the reaction performance followed the order of Dc > A > B > Pt > α. Through a comparative analysis of geometrical characteristics of the structural parameters and the reaction performance of the reactor, the results indicated that the radial projected area of the heat exchange tube is the dominant factor in the reaction performance of DHER. Moreover, the surface was calculated based on the sensitivity analysis data and fitted by the quadratic response surface regression model to predict the reaction time under different structural parameters, which may provide guidance for the design of reactors. In addition, the hydriding and dehydriding cyclic processes without preheating and precooling stages were confirmed to have prominent and reliable performances for DHER, attaining only 1227 s under its optimal cycle conditions during absorption (0.8 MPa, 273.15 K) and desorption (0.1 MPa, 373.15 K).
関連文献
A robust and versatile host–guest peptide toolbox for developing highly stable and specific quantum dot-based peptide probes for imaging extracellular matrices and cells
Bo Wang, Linge Nian, Sha Zhao, Jianxi Xiao
DOI: 10.1039/D3TB02749J
An investigation into the effects of ink formulations of semi-solid extrusion 3D printing on the performance of printed solid dosage forms
Peter Belton, Andrew Gleadall, Richard Bibb, Sheng Qi
DOI: 10.1039/D3TB01868G
Unlocking the biosynthetic regulation role of polyketide alkaloid lydicamycins
Xuanlin Zhan, Xiaojie Li, Yunyan Zeng, Siyan Jiang, Chao Pan, Shiyu Pan, Jiaquan Huang, Heqian Zhang, Zhiwei Qin
DOI: 10.1039/D3NJ05152H
Vancomycin-loaded hydrogels with thermal-responsive, self-peeling, and sustainable antibacterial properties for wound dressing
Yun Tang, Xinrui Shu, Guandi He, Yuhan Zhang, Yonghe Zhao, Hudie Yuan, Jingjie Yu, Jiabao Guo, Qiang Chen
DOI: 10.1039/D3TB02084C
Intestinal retentive systems – recent advances and emerging approaches
Durva A. Naik, Spencer Matonis, Gaurav Balakrishnan
DOI: 10.1039/D3TB01842C
Application of micro/nanomotors in environmental remediation
Dan Jing, Ziyi Li, Wennan Yan, Ji Zhang, Yingshu Guo
DOI: 10.1039/D3NJ04873J
Two new 6-nitrobenzimidazole ligand-modified polymolybdate-based metal–organic complexes with excellent capacitive and electrocatalytic performances
Ju-Ju Liang, Yu-Chen Zhang, Zhi-Han Chang, Yong-Zhen Chen, Ke-Ke Chen, Jun-Jun Lu, Xiu-Li Wang
DOI: 10.1039/D3NJ04841A
Green and efficient preparation and application of weakly crystalline TiO2 with high catalytic activity
Ying Feng, YongChao Zhu, Tian Chen, Pengcheng Li, Bingjie Liu, Jianfeng Cai, Wenjie Liang, Hai Xu
DOI: 10.1039/D3NJ05125K
Towards improved comprehensive energetic properties by skeleton modification
DOI: 10.1039/D3NJ05248F
A novel magnetically guided, oxygen propelled CoPt/Au nanosheet motor in conjugation with a multilayer hollow microcapsule for effective drug delivery and light triggered drug release
Samira Kariminia, Mojtaba Shamsipur, Kamran Mansouri
DOI: 10.1039/D3TB01888A
こちらもおすすめ
3-(5-フェニル-2-ファイル)-プロパン酸の市場動向や研究トレンドはどうですか?
この化合物の市場動向は不明ですが、類似化合物の需要は化学繊維、医薬品、農薬分野で安定しています。研究トレンドとしては、該当化合物の生物学的活性の評価や、その他の...
3- Chloro-1H-indazol-5-olはどのように保存すればよいですか?
3- チロロ-1H-吲唑-5-醇は遮光し、直射日光を避けて、温度は室温を推奨し、密閉容器に保存してください。
L-(1-~13~C)メチオニンの市場動向や研究トレンドはどうですか?
L-(1-~13~C)メチオニンは、医薬品やバイオテクノロジー分野での研究が増加しており、その価格は安定しています。新興研究分野では、代謝解析や遺伝子機能解析で...
1,3-フェニレンビスメチレンビスアクリレートは安全ですか?
1,3-フェニレンビスメチレンビスアクリレートは一般的に安全ですが、直接皮膚に触れる場合は保護用具を使用することを推奨します。高濃度の蒸気が吸入された場合は呼吸...
丹参醇Aはどのように保存すればよいですか?
丹参醇Aは、直射日光を避けて室温で保存し、密栓容器に入れることをお勧めします。適切な保存条件は、安定性を保ち、安全性を確保する上で重要です。
4-メチル-2-(1,1,1-三フロロ-2-メチルプロパニル)ピリドインとは何ですか?
CAS番号1378865-93-0の4-メチル-2-(1,1,1-三フロロ-2-メチルプロパニル)ピリドインは、合成化学分野で用いられる有機化合物の一種です。こ...
N-フェニルベンジル-2-クロロ酢氨を取り扱う際の実験室安全事項は何ですか?
N-フェニルベンジル-2-クロロ酢氨は毒性があり、皮膚や粘膜に刺激を与えます。取り扱う際には、保護眼鏡、手袋、ゴーグルを着用することを強く推奨します。ドラフトチ...
UCN-02を取り扱う際の実験室安全事項は何ですか?
UCN-02は毒性は低いですが、人体への直接的な接触は避けるべきです。PPE要件はグローブと顔面保護具を着用することです。ドラフトチャンバーを使用して漏洩を処理...
N-[3-[2-(二甲基氨基)乙氧基]-4-甲氧基苯基]-2'-甲基-4'-(5-甲基-1,2,4-恶二唑-3-基)-[1,1'-联苯]-4-甲酰胺を取り扱う際の実験室安全事項は何ですか?
手袋と保護眼鏡を着用し、漏洩時には吸気防止装置を使用してください。室温、乾燥した場所に保管し、直日光から隔離してください。SDS(安全データシート)を参照してく...











![2,2'-{2,2-Propanediylbis[(2,6-dibromo-4,1-phenylene)oxy]}diethanol structure 2,2'-{2,2-Propanediylbis[(2,6-dibromo-4,1-phenylene)oxy]}diethanol structure](https://static.chemtradehub.com/structs/416/4162-45-2-b3d6.webp)
![N-[(E)-Phenylmethylene]benzenesulfonamide structure N-[(E)-Phenylmethylene]benzenesulfonamide structure](https://static.chemtradehub.com/structs/139/13909-34-7-8167.webp)


![5-Bromoimidazo[1,2-a]pyridine structure 5-Bromoimidazo[1,2-a]pyridine structure](https://static.chemtradehub.com/structs/692/69214-09-1-d8e2.webp)