Microfluidic compartments with sensing microbeads for dynamic monitoring of cytokine and exosome release from single cells

文献情報

出版日 2015-10-05
DOI 10.1039/C5AN01648G
インパクトファクター 4.616
著者

Kyung Jin Son, Ali Rahimian, Christian Siltanen, Tushar Patel, Alexander Revzin


原文を見る

要旨

Monitoring activity of single cells has high significance for basic science and diagnostic applications. Here we describe a reconfigurable microfluidic device for confining single cells along with antibody-modified sensing beads inside 20 picoliter (pL) microcompartments for monitoring cellular secretory activity. An array of ∼7000 microchambers fabricated in the roof of the reconfigurable microfluidic device could be raised or lowered by applying negative pressure. The floor of the device was micropatterned to contain cell attachment sites in registration with the microcompartments. Using this set-up, we demonstrated the detection of inflammatory cytokine IFN-γ and exosomes from single immune cells and cancer cells respectively. The detection scheme was similar in both cases: cells were first captured on the surface inside the microfluidic device, then sensing microbeads were introduced into the device so that, once the microcompartments were lowered, single cells and microbeads became confined together. The liquid bathing the beads and the cells inside the compartments also contained fluorescently-labeled secondary antibodies (Abs). The capture of cell-secreted molecules onto microbeads was followed by binding of secondary antibodies – this caused microbeads to become fluorescent. The fluorescence intensity of the microbeads changed over time, providing dynamics of single cell secretory activity. The microdevice described here may be particularly useful in the cases where panning upstream of sensing is required or to analyze secretory activity of anchorage-dependent cells.

関連文献

Controlled self-assembly and templated metallization of fibrinogen nanofibrils

Gang Wei, Jörg Reichert, Klaus D. Jandt

2008-06-27 Communication

DOI: 10.1039/B806316H

Chemoselective derivatization of alkaloids in periwinkle

M. Carmen Galan, Elizabeth McCoy, Sarah E. O'Connor

2007-07-11 Communication

DOI: 10.1039/B708919H

Hybrid materials with nanoscopic anion-binding pockets for the colorimetric sensing of phosphate in water using displacement assays

María Comes, María D. Marcos, Ramón Martínez-Máñez, Félix Sancenón, Juan Soto, Luis A. Villaescusa, Pedro Amorós

2008-06-11 Communication

DOI: 10.1039/B804396E

Catalytic asymmetric deprotonation of phosphine boranes and sulfides as a route to P-stereogenic compounds

Jonathan J. Gammon, Steven J. Canipa, Peter O’Brien, Brian Kelly, Sven Taylor

2008-07-17 Communication

DOI: 10.1039/B806864J

Reversible solid optical sensor based on acyclic-type receptor immobilized SBA-15 for the highly selective detection and separation of Hg(ii) ion in aqueous media

Eunjeong Kim, Hee Eun Kim, Soo Jin Lee, Shim Sung Lee, Moo Lyong Seo, Jong Hwa Jung

2008-07-02 Communication

DOI: 10.1039/B806019C

Front cover

Cover

DOI: 10.1039/B812523F

Thermally stable and photoreactive polylactides by the terminal conjugation of bio-based caffeic acid

Michiya Matsusaki, Mitsuru Akashi

2008-07-02 Communication

DOI: 10.1039/B803615B

Direct synthesis of oxazolines from olefins and amides using t-BuOI

Satoshi Minakata, Yoshinobu Morino, Toshihiro Ide, Yoji Oderaotoshi, Mitsuo Komatsu

2007-06-07 Communication

DOI: 10.1039/B706572H

こちらもおすすめ

化合物よくある質問

3-(5-フェニル-2-ファイル)-プロパン酸の市場動向や研究トレンドはどうですか?

この化合物の市場動向は不明ですが、類似化合物の需要は化学繊維、医薬品、農薬分野で安定しています。研究トレンドとしては、該当化合物の生物学的活性の評価や、その他の...

3465-61-03-(5-Phenyl-2-furyl)...
化合物よくある質問

3- Chloro-1H-indazol-5-olはどのように保存すればよいですか?

3- チロロ-1H-吲唑-5-醇は遮光し、直射日光を避けて、温度は室温を推奨し、密閉容器に保存してください。

885519-34-63-Chloro-1H-indazol-...
化合物よくある質問

二茂鐵是安全的吗?

二茂鐵在使用时需要谨慎,因为它具有一定的刺激性。在操作时应佩戴防护眼镜和手套,保持通风良好的环境,并避免皮肤接触和吸入。

849924-76-11,2,3,4,5-Cyclopenta...
化合物よくある質問

L-(1-~13~C)メチオニンの市場動向や研究トレンドはどうですか?

L-(1-~13~C)メチオニンは、医薬品やバイオテクノロジー分野での研究が増加しており、その価格は安定しています。新興研究分野では、代謝解析や遺伝子機能解析で...

81202-04-2L-(1-~13~C)Methionin...
化合物よくある質問

1,3-フェニレンビスメチレンビスアクリレートは安全ですか?

1,3-フェニレンビスメチレンビスアクリレートは一般的に安全ですが、直接皮膚に触れる場合は保護用具を使用することを推奨します。高濃度の蒸気が吸入された場合は呼吸...

22757-16-01,3-Phenylenebis(met...
化合物よくある質問

丹参醇Aはどのように保存すればよいですか?

丹参醇Aは、直射日光を避けて室温で保存し、密栓容器に入れることをお勧めします。適切な保存条件は、安定性を保ち、安全性を確保する上で重要です。

189308-08-5Danshenol A
化合物よくある質問

4-メチル-2-(1,1,1-三フロロ-2-メチルプロパニル)ピリドインとは何ですか?

CAS番号1378865-93-0の4-メチル-2-(1,1,1-三フロロ-2-メチルプロパニル)ピリドインは、合成化学分野で用いられる有機化合物の一種です。こ...

1378865-93-04-Methyl-2-(1,1,1-tr...
化合物よくある質問

N-フェニルベンジル-2-クロロ酢氨を取り扱う際の実験室安全事項は何ですか?

N-フェニルベンジル-2-クロロ酢氨は毒性があり、皮膚や粘膜に刺激を与えます。取り扱う際には、保護眼鏡、手袋、ゴーグルを着用することを強く推奨します。ドラフトチ...

2653-14-7N-benzyl-2-chloro-N-...
化合物よくある質問

UCN-02を取り扱う際の実験室安全事項は何ですか?

UCN-02は毒性は低いですが、人体への直接的な接触は避けるべきです。PPE要件はグローブと顔面保護具を着用することです。ドラフトチャンバーを使用して漏洩を処理...

化合物よくある質問

N-[3-[2-(二甲基氨基)乙氧基]-4-甲氧基苯基]-2'-甲基-4'-(5-甲基-1,2,4-恶二唑-3-基)-[1,1'-联苯]-4-甲酰胺を取り扱う際の実験室安全事項は何ですか?

手袋と保護眼鏡を着用し、漏洩時には吸気防止装置を使用してください。室温、乾燥した場所に保管し、直日光から隔離してください。SDS(安全データシート)を参照してく...

170230-39-4N-{3-[2-(Dimethylami...

掲載誌

Analyst

Analyst
CiteScore: 7.8
自己引用率: 5.6%
年間論文数: 653

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.

おすすめ化合物

おすすめサプライヤー

免責事項
このページに表示される学術雑誌情報は、参考および研究目的のみを目的としています。当社は雑誌出版社とは提携しておらず、投稿の取り扱いも行っておりません。出版に関するお問い合わせは、各雑誌出版社に直接ご連絡ください。
表示されている情報に誤りがある場合は、support@chemtradehub.com までご連絡ください。迅速に確認し、対応いたします。