The analytical utility of thermally desorbed polydimethylsilicone membranes for in-vivo sampling of volatile organic compounds in and on human skin

文献情報

出版日 2008-05-20
DOI 10.1039/B802515K
インパクトファクター 4.616
著者

S. Riazanskaia, G. Blackburn, M. Harker, D. Taylor, C. L. P. Thomas


原文を見る

要旨

A thermally-desorbed polydimethylsilicone (PDMS) membrane approach with analysis by gas chromatography-mass spectrometry has been developed and characterised, to enable the VOC arising in, and on skin, from glandular secretions, exogenous materials, products of perfusion from blood, and microbiological metabolites to be sampled in a single procedure. In-vitro studies using a series of volatile fatty acid standards indicated that the recovery efficiency of the technique increased with decreasing volatility; for example, the recovery of hexanoic acid was 3.3 times greater than that for 2-methylpropanoic acid. The relative standard deviation of the methodology decreased with decreasing volatility; RSD = 19% for 2-methylpropanoic acid and RSD = 7% for hexanoic acid. Sampled-mass vs. response relationships were modelled satisfactorily using linear regression analysis with regression coefficients in the range 0.95 to 0.998. In-vivo reproducibility was assessed though the analysis of the responses of 1-dodecane, 3,7-dimethyloct-1-ene, 2-propenoic acid, 2-ethylhexyl ester, 2-ethylhexan-1-ol, butanoic, 2-ethylhexylester, and junipen (1,4-methanoazulene, decahydro-4,8,8-trimethyl-9-methylene-); six compounds selected at random retention times from a GC-MS chromatographic VOC profile of human skin containing several hundred resolved and partially resolved compounds. Five samples were obtained simultaneously from the forearm of a healthy male participant. The in-vivo sample masses were estimated to be in the range 50 pg to 100 ng per sample with observed RSD falling between 15% and 32%; in line with a Horwitz trend. Increasing the sample time from 5 min to 120 min generally resulted in an enrichment of the VOC recovered, and for many VOC substantial increases in sensitivity (×7) were observed over this time range as the PDMS sampling-patch approached equilibrium with the underlying skin. Nevertheless, more volatile components, 2,4,6-trimethylcarbazole for instance, were observed to be lost from the analysis with increasing sample time, in a manner analogous with breakthrough behaviour in adsorbent traps. Finally, a 10 day storage study at 4 °C suggested that micro-biological factors were significant in their effect on sample stability. Significant changes (up to ×8) were observed in the masses of compounds recovered post storage. These studies confirmed that polydimethylsilicone membrane sampling patches of human skin provide rich and analytical useful data. It is important to note that care in experimental design is needed to avoid sampling artefacts being introduced through sampling selectivity, and/or, sample instability where samples are stored for longer than 24 h at 4 °C or higher.

関連文献

Fabrication of an amperometric bienzyme biosensing system with neutral red functionalized carbon nanotubes

D. R. Shobha Jeykumari, S. Sriman Narayanan

2009-05-19 Paper

DOI: 10.1039/B820040H

An ultra-fast UV-electrochemical sensor based on Cu-MOF for highly sensitive and selective detection of ferric ions

Xiaoqin Wu, Juanli Xi, Xuehong Wei, Caixia Yin

2022-12-09 Paper

DOI: 10.1039/D2AN01865A

Contents list

2022-12-05 Front/Back Matter

DOI: 10.1039/D2AN90096C

UV-PEDD photometry dedicated for bioanalytical uses

Łukasz Tymecki, Luiza Brodacka, Beata Rozum, Robert Koncki

2009-03-13 Paper

DOI: 10.1039/B822025E

Coil spring-powered pump with inertial microfluidic chip for size-based isolation and enrichment of biological cells

Hogyeong Gwak, Seong Min Ha, Jae-Woo Song, Kyung-A. Hyun

2022-11-11 Paper

DOI: 10.1039/D2AN01380K

Detection ofdrug-induced cellular changes using confocal Raman spectroscopy on patterned single-cell biosensors

Ryan Buckmaster, Fareid Asphahani, Myo Thein, Jian Xu, Miqin Zhang

2009-04-30 Paper

DOI: 10.1039/B900420C

Quantitative assessment of intracellular/extracellular dimethyl sulfoxide concentrations during freezing with low-temperature confocal Raman micro-spectroscopy

Taijie Zhan, Wenya Niu, Mengdong Cui, Hengxin Han, Ding Wang, Yi Xu

2022-10-19 Paper

DOI: 10.1039/D2AN01288J

こちらもおすすめ

化合物よくある質問

2,3-スチオエポキシマドルを取り扱う際の実験室安全事項は何ですか?

取り扱いにはPPE(プロテクティブ・パーソナル・エイド)が必要で、防ぐ手袋と保護眼鏡を着用してください。ドラフトチャンバーの使用を推奨します。漏洩した場合は、適...

4267-80-52,3-Thioepoxy Madol
化合物よくある質問

6-氟-2-氨基苯酚の主な用途は何ですか?

6-氟-2-氨基苯酚は主に医薬品の合成材料として使用され、一部の農薬の製造にも利用されます。また、研究用途でも広く使用されています。

53981-25-22-Amino-6-fluorophen...
化合物よくある質問

BOC-S-3-アミニ-4-(4-メチオキシベンチル)-ブタン酸の代替品はありますか?

この化合物の代替品としては、BOC保護基を有さないアミノ酸やその他の保護基化合物が考えられます。また、メチオキシ基を有しない他の芳香族アミノ酸も代替品として挙げ...

126800-59-7(3S)-4-(4-Methoxyphe...
化合物よくある質問

Methyl 2-(chloromethyl)-3-nitrobenzoate(1218910-61-2)の代替品はありますか?

Methyl 2-(chloromethyl)-3-nitrobenzoate(1218910-61-2)の代替品としては、化学組成を変えることで効果を達成する...

1218910-61-2Methyl 2-(chlorometh...
化合物よくある質問

(2R)-2-アミノ-N-ベンジル-3-ヒドロキシプロパナミドを含む廃棄物はどのように処理すべきですか?

(2R)-2-アミノ-N-ベンジル-3-ヒドロキシプロパナミドを含む廃棄物は、適切な廃棄物管理ガイドラインに基づき処理する必要があります。まず、廃棄物を適切に収...

175481-39-7(2R)-2-amino-N-benzy...
化合物よくある質問

6,7-二氢-咪唑並[1,2-a]ピリドイン-8(5h)-酮はどのように合成されますか?

6,7-二氢-咪唑並[1,2-a]ピリドイン-8(5h)-酮は、2-ブロモフェニルアセトインとリン酸ハロゲン化物を反応させることで合成できます。この反応は高温で...

457949-09-66,7-Dihydroimidazo[1...
化合物よくある質問

エチル(3R)-3-ピロリジニル酢酸水和塩とは何ですか?

エチル(3R)-3-ピロリジニル酢酸水和塩は、CAS番号1332459-32-1の化合物で、(R)-乙基2-(ピロリジン-3-基)酢酸塩水和塩と呼ばれます。この...

1332459-32-1Ethyl (3R)-3-pyrroli...
化合物よくある質問

(2S)-{[(2-メチルエチルオキシ]カルボニル}アミノ)[2-(トリアフルオロメチルフェニル]エチカシック酸の物理化学的性質は何ですか?

(2S)-{[(2-メチルエチルオキシ]カルボニル}アミノ)[2-(トリアフルオロメチルフェニル]エチカシック酸のCAS番号は1203454-45-8です。この...

1203454-45-8(2S)-({[(2-Methyl-2-...
化合物よくある質問

2-ブロモ-1-(2-メチル-2-プロパニル)-4-ニトロベンゼンはどのように保存すればよいですか?

2-ブロモ-1-(2-メチル-2-プロパニル)-4-ニトロベンゼンは、直射日光を避けて暗所で、室温(約15℃〜25℃)、乾燥した場所に保存する必要があります。ま...

6310-17-42-Bromo-1-(2-methyl-...
化合物よくある質問

1-[(4-硝基フェニル)スルホニル]-1H-1,2,4-三唑の市場動向や研究トレンドはどうですか?

市場動向としては、1-[(4-硝基フェニル)スルホニル]-1H-1,2,4-三唑は主に農業用除草剤や合成化学製品の原料として利用されています。研究トレンドとして...

57777-84-11-[(4-Nitrophenyl)su...

掲載誌

Analyst

Analyst
CiteScore: 7.8
自己引用率: 5.6%
年間論文数: 653

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.

おすすめサプライヤー

免責事項
このページに表示される学術雑誌情報は、参考および研究目的のみを目的としています。当社は雑誌出版社とは提携しておらず、投稿の取り扱いも行っておりません。出版に関するお問い合わせは、各雑誌出版社に直接ご連絡ください。
表示されている情報に誤りがある場合は、support@chemtradehub.com までご連絡ください。迅速に確認し、対応いたします。