Raman spectroscopic monitoring of droplet polymerization in a microfluidic device
文献情報
Susan E. Barnes, Zuzanna T. Cygan, Jesse K. Yates, Kathryn L. Beers, Eric J. Amis
Microfluidic methodologies are becoming increasingly important for rapid formulation and screening of materials, and development of analytical tools for multiple sample screening is a critical step in achieving a combinatorial ‘lab on a chip’ approach. This work demonstrates the application of Raman spectroscopy for analysis of monomer composition and degree of conversion of methacrylate-based droplets in a microfluidic device. Droplet formation was conducted by flow focusing on the devices, and a gradient of component composition was created by varying the flow rates of the droplet-phase fluids into the microchannels. Raman data were collected using a fiber optic probe from a stationary array of the droplets/particles on the device, followed by partial least squares (PLS) calibration of the first derivative (1600 cm−1 to 1550 cm−1) allowing successful measurement of monomer composition with a standard error of calibration (SEC) of ±1.95% by volume. Following photopolymerization, the percentage of double bond conversion of the individual particles was calculated from the depletion of the normalized intensity of the CC stretching vibration at 1605 cm−1. Raman data allowed accurate measurement of the decrease in double bond conversion as a function of increasing crosslinker concentration. The results from the research demonstrate that Raman spectroscopy is an effective, on-chip analytical tool for screening polymeric materials on the micrometre scale.
関連文献
Efficient calculation of femtosecond time-resolved photoelectron spectra: method and application to the ionization of pyrazine
DOI: 10.1039/B100168J
Neodymium catalysts for polymerization of dienes, vinyl monomers, and ε-caprolactone
Hanghang Wang, John Michael O. Cue, Erika L. Calubaquib, Ruvanthi N. Kularatne, Somayeh Taslimy, Justin T. Miller, Mihaela C. Stefan
DOI: 10.1039/D1PY01270C
Numbers and densities of states and partition functions from an efficient approach to phase space integration
Stefan Schmatz
DOI: 10.1039/B009788H
Absorption and electroabsorption spectra of [(NH3)5Ru–pyrazine]2+ and [(NH3)5Ru–pyrazine–H]3+ by a vibronic model Hamiltonian
Alessandro Ferretti, Roberto Improta, Alessandro Lami, Giovanni Villani
DOI: 10.1039/B008278N
Phase behaviour of quaternary systems containing carbohydrate surfactants–water–oil–cosurfactant
DOI: 10.1039/A907015J
Effect of temperature on the molar conductivity of aqueous solutions of sodium and calcium fullerenehexamalonates, Th-C66(COONa)12 and Th-C66((COO)2Ca)6
Aleksander Vrhovšek, Janez Cerar, Marija Bešter-Rogač, Jože Škerjanc
DOI: 10.1039/B101625N
The structure of gelatin–water/oil microemulsion sols and gels. An EPR spin-probe and spin-labelling study
DOI: 10.1039/A906186J
Unimolecular and bimolecular reactions of state selected HCl+ ions formed via the R(1) pump line of the f3Δ2←1Σ+ REMPI spectrum
DOI: 10.1039/B009790J
こちらもおすすめ
3-(5-フェニル-2-ファイル)-プロパン酸の市場動向や研究トレンドはどうですか?
この化合物の市場動向は不明ですが、類似化合物の需要は化学繊維、医薬品、農薬分野で安定しています。研究トレンドとしては、該当化合物の生物学的活性の評価や、その他の...
3- Chloro-1H-indazol-5-olはどのように保存すればよいですか?
3- チロロ-1H-吲唑-5-醇は遮光し、直射日光を避けて、温度は室温を推奨し、密閉容器に保存してください。
L-(1-~13~C)メチオニンの市場動向や研究トレンドはどうですか?
L-(1-~13~C)メチオニンは、医薬品やバイオテクノロジー分野での研究が増加しており、その価格は安定しています。新興研究分野では、代謝解析や遺伝子機能解析で...
1,3-フェニレンビスメチレンビスアクリレートは安全ですか?
1,3-フェニレンビスメチレンビスアクリレートは一般的に安全ですが、直接皮膚に触れる場合は保護用具を使用することを推奨します。高濃度の蒸気が吸入された場合は呼吸...
丹参醇Aはどのように保存すればよいですか?
丹参醇Aは、直射日光を避けて室温で保存し、密栓容器に入れることをお勧めします。適切な保存条件は、安定性を保ち、安全性を確保する上で重要です。
4-メチル-2-(1,1,1-三フロロ-2-メチルプロパニル)ピリドインとは何ですか?
CAS番号1378865-93-0の4-メチル-2-(1,1,1-三フロロ-2-メチルプロパニル)ピリドインは、合成化学分野で用いられる有機化合物の一種です。こ...
N-フェニルベンジル-2-クロロ酢氨を取り扱う際の実験室安全事項は何ですか?
N-フェニルベンジル-2-クロロ酢氨は毒性があり、皮膚や粘膜に刺激を与えます。取り扱う際には、保護眼鏡、手袋、ゴーグルを着用することを強く推奨します。ドラフトチ...
UCN-02を取り扱う際の実験室安全事項は何ですか?
UCN-02は毒性は低いですが、人体への直接的な接触は避けるべきです。PPE要件はグローブと顔面保護具を着用することです。ドラフトチャンバーを使用して漏洩を処理...
N-[3-[2-(二甲基氨基)乙氧基]-4-甲氧基苯基]-2'-甲基-4'-(5-甲基-1,2,4-恶二唑-3-基)-[1,1'-联苯]-4-甲酰胺を取り扱う際の実験室安全事項は何ですか?
手袋と保護眼鏡を着用し、漏洩時には吸気防止装置を使用してください。室温、乾燥した場所に保管し、直日光から隔離してください。SDS(安全データシート)を参照してく...
掲載誌
Analyst

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.













![5-Bromoimidazo[1,2-a]pyridine structure 5-Bromoimidazo[1,2-a]pyridine structure](https://static.chemtradehub.com/structs/692/69214-09-1-d8e2.webp)
![2,9-Dichloro-5,12-dihydroquinolino[2,3-b]acridine-7,14-dione structure 2,9-Dichloro-5,12-dihydroquinolino[2,3-b]acridine-7,14-dione structure](https://static.chemtradehub.com/structs/308/3089-17-6-750b.webp)