A simple calibration procedure for volatile organic compounds sampling in air with adsorptive solid-phase microextraction fibres

文献情報

出版日 2003-06-25
DOI 10.1039/B300968H
インパクトファクター 4.616
著者

Ludovic Tuduri, Valérie Desauziers, Jean Louis Fanlo


原文を見る

要旨

Adsorptive solid-phase microextraction (SPME) fibres have proven to be a reliable means of sampling volatile organic compounds (VOCs) in air. In this work, polydimethylsiloxane/carboxen (PDMS/CAR) fibres were used to test a new approach of air sampling strategy with SPME in the lab which could lighten calibration procedure and enhance the use of this already rapid, simple, convenient and cost effective sampling technique. Indeed, only one curve can be used whatever the extraction time chosen by the analyst under constant conditions of air velocity and temperature. Ficks' law of diffusion was used to model SPME grab sampling when the fibre was totally exposed to the air sample. Experimental sampling rates were then determined by GC-FID for different sampling conditions, i.e. in a flowing air stream of known velocity (“dynamic mode”) and in a stagnant air (“static mode”). These sampling rates were found to be 3.50 and 17.80 mL min−1 for acetone, 4.06 and 21.20 mL min−1 for 1,2-dichloroethane, 5.10 and 27.80 mL min−1 for toluene and 5.36 and 30.80 mL min−1 for butyl acetate, for static and dynamic sampling modes respectively. Deviation from linearity of the calibration curves, indicating that a significant fraction of the adsorption sites are occupied, were determined. They were found to be approximately equal to 0.9, 1.57, 3.82 and 4.37 nmol for acetone, dichloroethane, toluene and butyl acetate, respectively. Experimentally determined sampling rates of these isolated compounds were also valid when a complex equimolar gaseous mixture was investigated, but deviation from linearity appears earlier. Then, for a given application, sampling times should be chosen very carefully to avoid competitive adsorption and hence, bad quantitative analysis results.

関連文献

Probing micro-solvation in “numbers”: the case of neutral dipeptides in water

Panteleimon G. Takis, Konstantinos D. Papavasileiou, Loukas D. Peristeras, Vasilios S. Melissas, Anastassios N. Troganis

2013-03-22 Paper

DOI: 10.1039/C3CP44606A

In situ high pressure NMR study of the direct synthesis of NaAlH4

Terry D. Humphries, Derek Birkmire, Bjørn C. Hauback, G. Sean McGrady, Craig M. Jensen

2013-03-04 Communication

DOI: 10.1039/C3CP50777G

Photoinduced energy and charge transfer in a p-phenylene-linked dyad of boron dipyrromethene and monostyryl boron dipyrromethene

Roel Menting, Jian-Yong Liu, Ying-Si Huang, Dennis K. P. Ng, Beate Röder

2013-03-15 Paper

DOI: 10.1039/C3CP50576F

Inside front cover

Cover

DOI: 10.1039/C3CP90043F

Laser directed lithography of asymmetric graphene ribbons on a polydimethylsiloxane trench structure

Yi Yang, Dan Xie, Tian-Ling Ren, Yi Shu, Hui Sun, Chang-Jian Zhou, Xuan Liu, Lu-Qi Tao, Jie Ge, Cang-Hai Zhang, Yuegang Zhang

2013-02-28 Paper

DOI: 10.1039/C3CP50538C

Ultrafast photoinduced dynamics of halogenated cyclopentadienes: observation of geminate charge-transfer complexes in solution

T. J. A. Wolf, R. Radloff, P. Lang, A. Stolow, A.-N. Unterreiner

2013-02-11 Paper

DOI: 10.1039/C3CP44295K

A statistical approach for analyzing the development of 1H multiple-quantum coherence in solids

Yuuki Mogami, Yasuto Noda, Hiroto Ishikawa, K. Takegoshi

2013-04-12 Paper

DOI: 10.1039/C3CP43778G

Experimental visualization of the Bi–O covalency in ferroelectric bismuth ferrite (BiFeO3) by synchrotron X-ray powder diffraction analysis

Kotaro Fujii, Hiroki Kato, Kazuki Omoto, Jun Chen, Xianran Xing

2013-03-14 Communication

DOI: 10.1039/C3CP50236H

Hydrogen adsorption and desorption at the Pt(110)-(1×2) surface: experimental and theoretical study

Kees-Jan Weststrate, Ludo Juurlink

2013-03-05 Paper

DOI: 10.1039/C3CP44503H

Rotational spectroscopy meets theory

Cristina Puzzarini

2013-02-19 Perspective

DOI: 10.1039/C3CP44301A

こちらもおすすめ

化合物よくある質問

2-ブロモ-9,9-ジフェニル-9H-フルオレンの主な用途は何ですか?

2-溴-9,9-二苯基芴は、医薬品、工業材料、有機合成の研究分野で応用されます。特に、レーザー材料や機能性ポリマーの合成に使用されることがあります。また、蛍光色...

474918-32-62-Bromo-9,9-diphenyl...
化合物よくある質問

四氯化铱の市場動向や研究トレンドはどうですか?

四氯化铱の市場は研究開発分野で注目されており、特にナノ技術や金属有機框架(MOFs)の分野での需要が増加傾向にあります。価格は安定しており、中国や韓国での生産が...

207399-11-9Tetrachloroiridium h...
化合物よくある質問

4-硝基肉桂酸はどの業界で使用されていますか?

4-硝基肉桂酸は主に医薬品業界で使用されています。また、センサー開発や半導体製造業界でも応用されています。

882-06-44-Nitrocinnamic acid
化合物よくある質問

1-(4-溴-3-氟苯基)-2-氯乙酮を含む廃棄物はどのように処理すべきですか?

1-(4-溴-3-氟苯基)-2-氯乙酮 (CAS番号: 1260857-14-4) の廃棄物は専門的な廃棄処理が必要です。まず、廃棄物は密閉された容器に収集し、...

1260857-14-41-(4-Bromo-3-fluorop...
化合物よくある質問

苦参酚Kとは何ですか?

苦参酚Kは、CAS番号101236-49-1を持つ化合物で、主に天然由来の生薬から抽出されます。この化合物は、抗炎症作用や抗癌作用を持つことが報告されています。

101236-49-1Kushenol K
化合物よくある質問

POTASSIUM (1-(TERTBUTOXYCARBONYL)AZETIDIN-3-YL)TRIFLUOROBORATE を含む廃棄物はどのように処理すべきですか?

POTASSIUM (1-(TERTBUTOXYCARBONYL)AZETIDIN-3-YL)TRIFLUOROBORATE を含む廃棄物は、まず安全なエント...

1430219-73-0Potassium (1-(tert-b...
化合物よくある質問

4-庚基-4’-联苯羧酸の市場動向や研究トレンドはどうですか?

4-庚基-4’-聯苯羧酸は、特殊化学品や合成化学の分野で用いられる化学物質ですが、市場動向としては、研究開発の進展とともに需要が増加しています。また、環境配慮型...

58573-94-74'-Heptyl-4-biphenyl...
化合物よくある質問

6-ブロモ-3-メトキシ-1-フェニル-1H-インドゾールを含む廃棄物はどのように処理すべきですか?

6-ブロモ-3-メトキシ-1-フェニル-1H-インドゾールを含む廃棄物は、適切な化学廃棄処理が必要です。通常、廃棄物は密閉容器に収集され、専門の廃棄処理業者に引...

1332527-03-36-Bromo-3-methoxy-1-...
化合物よくある質問

4,4-二甲基-2-吡咯烷酮はどの業界で使用されていますか?

4,4-二甲基-2-吡咯烷酮は医薬、ポリマー、センサー、半導体などの業界で広く使用されています。特に溶媒としての性能が高く評価されています。

66899-02-34,4-dimethylpyrrolid...
化合物よくある質問

リン酸鉍はどのように保存すればよいですか?

リン酸鉍は遮光容器に保存し、乾燥した場所で常温で保管してください。

51312-42-6Sodium Phosphotungst...

掲載誌

Analyst

Analyst
CiteScore: 7.8
自己引用率: 5.6%
年間論文数: 653

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.

おすすめ化合物

おすすめサプライヤー

免責事項
このページに表示される学術雑誌情報は、参考および研究目的のみを目的としています。当社は雑誌出版社とは提携しておらず、投稿の取り扱いも行っておりません。出版に関するお問い合わせは、各雑誌出版社に直接ご連絡ください。
表示されている情報に誤りがある場合は、support@chemtradehub.com までご連絡ください。迅速に確認し、対応いたします。