Preparation of single-stranded PCR products for electrospray ionization mass spectrometry using the DNA repair enzyme lambda exonuclease

文献情報

出版日 2000-02-24
DOI 10.1039/A908022H
インパクトファクター 4.616
著者

Allison P. Null, James C. Hannis, David C. Muddiman


原文を見る

要旨

Electrospray ionization mass spectrometry (ESI-MS) has been utilized to obtain accurate mass measurements of intact PCR products; however, single-stranded PCR products are necessary to detect sequence modifications such as base substitutions, additions or deletions. The locations of these modifications can subsequently be determined using additional stages of mass spectrometry. The recombinant enzyme lambda exonuclease selectively digests one strand of a DNA duplex from a 5′ phosphorylated end leaving the complementary strand intact. Using this rapid enzymatic step, we were able to produce single-stranded PCR products by digestion of an intact PCR product derived from the Human Tyrosine Hydroxylase (HUMTHO1) gene, which contains a tetrameric repeating motif. The non-template directed 3′ adenylation common when using Taq polymerase resulted in three distinct species (blunt-ended, mono-adenylated and di-adenylated), which added complexity to the spectrum of the double-stranded product. The data from the single-stranded products shows that one strand is preferentially adenylated over the other, which cannot be determined from the mass spectrum of the double-stranded PCR product alone. The ESI-FTICR (Fourier transform ion cyclotron resonance) mass spectra of the lambda exonuclease treated PCR products exhibited less than expected signal-to-noise (S/N) ratios. This is attributed to inaccurate concentration calculations due to remaining double-stranded PCR product amplified with unphosphorylated primers, and to matrix effects contributed by the lambda exonuclease reaction buffer. To further test this hypothesis, we investigated and determined the limit of detection to be 0.27 μM using standard curve statistics for single acquisitions of a synthetic 75-mer. The concentrations of the noncoding and coding strands produced by lambda exonuclease digestion were calculated to be 0.29 and 0.37 μM, respectively, taking into account the presence of double-stranded product. The products were electrosprayed from concentrations at the limit of detection requiring the averaging of 5–10 acquisitions to produce a sufficient S/N ratio, indicating that product concentration, base composition and matrix effects play a combined, significant role in detection of lambda exonuclease treated PCR products. Although additional work will be required to further exploit this strategy, lambda exonuclease clearly provides mass spectrometrists with a method to generate single-stranded PCR products.

関連文献

Enhanced electrical properties and field emission characteristics of AZO/ZnO-nanowire core–shell structures

Jheng-Ming Huang, Shang-You Tsai, Ching-Shun Ku, Chih-Ming Lin, San-Yuan Chen

2016-05-09 Paper

DOI: 10.1039/C6CP01011C

Non-injection synthesis of monodisperse Cu–Fe–S nanocrystals and their size dependent properties

Grzegorz Gabka, Piotr Bujak, Jan Żukrowski, Damian Zabost, Kamil Kotwica, Karolina Malinowska, Andrzej Ostrowski, Ireneusz Wielgus, Wojciech Lisowski, Janusz W. Sobczak, Adam Pron

2016-05-05 Paper

DOI: 10.1039/C6CP01887D

Correlating structure and electronic band-edge properties in organolead halide perovskites nanoparticles

Qiushi Zhu, Alexander Generalov, Dörthe Haase, Stefan Carlson, Yuran Niu, Jimmy Heimdal, Anders Engdahl, Maria E. Messing, Tonu Pullerits

2016-05-10 Paper

DOI: 10.1039/C6CP01843B

Phase transitions in hydrophobe/phospholipid mixtures: hints at connections between pheromones and anaesthetic activity

Silvia Borsacchi, Marco Geppi, Sara Macchi, Emiliano Fratini, Moira Ambrosi

2016-05-06 Paper

DOI: 10.1039/C6CP00659K

Analysis of the magnetically induced current density of molecules consisting of annelated aromatic and antiaromatic hydrocarbon rings

Dage Sundholm, Raphael J. F. Berger, Heike Fliegl

2016-05-13 Paper

DOI: 10.1039/C6CP01968D

From dilute isovalent substitution to alloying in CdSeTe nanoplatelets

Ron Tenne, Miri Kazes, Sandrine Ithurria, Lothar Houben, Brice Nadal, Dan Oron, Benoit Dubertret

2016-05-05 Paper

DOI: 10.1039/C6CP01177B

Contents list

Front/Back Matter

DOI: 10.1039/C6CP90140A

Chemical vapor deposition of MoS2 layers from Mo–S–C–O–H system: thermodynamic modeling and validation

Sukanya Dhar, V. Kranthi Kumar, Tanushree H. Choudhury, S. A. Shivashankar, S. Raghavan

2016-05-05 Paper

DOI: 10.1039/C6CP01617K

こちらもおすすめ

化合物よくある質問

6-(三氟甲基)喹啉二甲酸とは何ですか?

6-(三氟甲基)喹啉二甲酸は、CAS番号849818-58-2の化合物です。これは6位に三氟甲基が置換された2-quinolinecarboxylic酸と呼ばれ...

849818-58-26-(Trifluoromethyl)-...
化合物よくある質問

tert-butyl 4-ヒドロキシ-4-メチルázepane-1-カーボキセイランを含む廃棄物はどのように処理すべきですか?

この化合物の廃棄物は、適切な容器で密封し、避光し、低温かつ乾燥した環境で保管してください。処理には専門の廃棄処理会社のサービスを活用するか、地元の環境保護法に従...

878631-04-02-Methyl-2-propanyl ...
化合物よくある質問

TIPAを取り扱う際の実験室安全事項は何ですか?

TIPAは揮発性が低く、毒性は低いですが、操作中の注意が必要です。PPE(個人防護具)を着用し、ドラフトチャンバー内で取り扱い、漏洩した場合は即座にSDS(安全...

化合物よくある質問

間三氟甲基苯乙酸甲酯の主な用途は何ですか?

間三氟甲基苯乙酸甲酯は主に合成化学において使用され、薬物合成の前駆体として利用されます。

62451-84-7Methyl 2-(3-(trifluo...
化合物よくある質問

3-甲硫基苯硼酸频呐酯とは何ですか?

3-甲硫基苯硼酸频呐酯は、CAS番号710348-63-3の化合物で、化学式はC14H19BO2Sです。これは2-[3-(メチルサルファニル)フェニル]-4,4...

710348-63-34,4,5,5-Tetramethyl-...
化合物よくある質問

N-[2-(二甲氨基)乙基]-N-甲基甲酰胺は安全ですか?

N-[2-(二甲氨基)乙基]-N-甲基甲酰胺は安全ではありません。吸入、皮膚接触、目接触は避けてください。稀な過剰反応やアレルギー反応がある可能性があります。適...

105669-53-2N-[2-(Dimethylamino)...
化合物よくある質問

甲基丙烯酸甲瓦龙酸内酯とは何ですか?

CAS番号177080-66-9の化合物、4-メチル-2-オキトテトラヒドロ-2H-ピラノ-4-イルメタクリレートは、甲基丙烯酸の一種です。この化合物は透明な液...

177080-66-94-Methyl-2-oxotetrah...
化合物よくある質問

2-メチルフェンチアルデヒドを取り扱う際の実験室安全事項は何ですか?

2-メチルフェンチアルデヒドは易燃物質であり、火気の使用や高温に注意が必要です。PPE(個人保護具)として、ゴーグルや手袋を使用し、ドラフトチャンバーを使用して...

51234-09-42-Methylveratraldehy...
化合物よくある質問

2,4,6-三氯-5-氟嘧啶はどの業界で使用されていますか?

2,4,6-三氯-5-氟嘧啶は医薬品産業で広く使用されており、抗真菌薬や抗ウイルス薬の前駆体として機能します。また、高次元材料やセンサー技術の分野でも応用されて...

6693-08-92,4,6-Trichloro-5-fl...
化合物よくある質問

(S)-2-((叔丁氧基羰基)氨基)-3-(((2-苯基乙酰胺基)甲基)硫基)丙酸とは何ですか?

CAS番号57084-73-8の(S)-2-((叔丁氧基羰基)氨基)-3-(((2-苯基乙酰胺基)甲基)硫基)丙酸は、特定の構造を持つ無機化合物で、主に医薬品や...

57084-73-8(S)-2-((tert-Butoxyc...

掲載誌

Analyst

Analyst
CiteScore: 7.8
自己引用率: 5.6%
年間論文数: 653

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.

おすすめサプライヤー

免責事項
このページに表示される学術雑誌情報は、参考および研究目的のみを目的としています。当社は雑誌出版社とは提携しておらず、投稿の取り扱いも行っておりません。出版に関するお問い合わせは、各雑誌出版社に直接ご連絡ください。
表示されている情報に誤りがある場合は、support@chemtradehub.com までご連絡ください。迅速に確認し、対応いたします。