The problem of background correction in the determination of chromium in urine by atomic absorption spectrometry with electrothermal atomisation
文献情報
A previously described positive interference in the determination of chromium in urine was ascribed to the failure of the deuterium arc background correction system to correct fully for background absorption. In this work, it is shown that the interference is dependent on the gain setting of the photomultiplier and on the atomisation temperature. At temperatures below 2400 °C the interference is absent, but on increasing the atomisation temperature from 2400 to 2700 °C the interference increases in severity. The interference is thought to be emission caused by chromium together with potassium and sodium in the matrix. Lowering the atomisation temperature to 2400 °C allows the determination of chromium in urine without significant interference using conventional deuterium arc background correction.
関連文献
Current-constrained one-electron reduced density-matrix theory for non-equilibrium steady-state molecular conductivity
Alexandra E. Raeber, David A. Mazziotti
DOI: 10.1039/C9CP01678C
Conformational dynamics and allosteric effect modulated by the unique zinc-binding motif in class IIa HDACs
Huawei Liu, Fan Zhang, Kai Wang, Xiaowen Tang, Ruibo Wu
DOI: 10.1039/C9CP02261A
Structure and dynamics of gold nanoparticles decorated with chitosan–gentamicin conjugates: ReaxFF molecular dynamics simulations to disclose drug delivery
Susanna Monti, Jiya Jose, Athira Sahajan, Nandakumar Kalarikkal, Sabu Thomas
DOI: 10.1039/C9CP02357G
Chemical pressure–chemical knowledge: squeezing bonds and lone pairs within the valence shell electron pair repulsion model
A. Lobato, H. H. Osman, M. A. Salvadó, M. Taravillo, J. M. Recio
DOI: 10.1039/C9CP00913B
Comparative study of the crowding-induced collapse effect in hard-sphere, flexible polymer and rod-like polymer systems
Anpu Chen, Nanrong Zhao
DOI: 10.1039/C9CP01731C
A new electrochemical cell with a uniformly accessible electrode to study fast catalytic reactions
Jean-Vincent Daurelle, Vincent Fourmond, Jérôme Vicente
DOI: 10.1039/C9CP01487J
Electronic structure and high-temperature thermochemistry of BaZrO3−δ perovskite from first-principles calculations
Krishna K. Ghose, Alicia Bayon, Alister J. Page
DOI: 10.1039/C9CP02505G
Adiabatic deprotonation as an important competing pathway to ESIPT in photoacidic 2-phenylphenols
Leandro D. Mena, D. M. A. Vera, Maria T. Baumgartner, Liliana B. Jimenez
DOI: 10.1039/C9CP02028D
Structures and dynamic properties of the LiPF6 electrolytic solution under electric fields – a theoretical study
Man Liu, Peter J. Chimtali, Xue-bin Huang, Ru-bo Zhang
DOI: 10.1039/C9CP00561G
こちらもおすすめ
S-(甲硅烷基丙基)異硫酰氯を取り扱う際の実験室安全事項は何ですか?
取り扱う際にはPPE(防護具)が必要です。特に手袋と面マスクは必須です。ドラフトチャンバーを使用して漏洩処理を行い、温度は常温、湿度は乾燥状態、容器はガラス容器...
8-硝基-咪唑并[1,2-a]吡啶とは何ですか?
8-硝基-咪唑并[1,2-a]吡啶は、CAS番号52310-46-0の化合物で、8-位に硝基を有する咪唑並みの结构をもつ吡啶の化合物です。この化合物は、酸化還元...
4-ブロモ-5-メトキシピリジン-2-甲醇の代替品はありますか?
4-ブロモ-5-メトキシピリジン-2-甲醇の代替品には、類似構造を持つ化合物や機能性に等しい代替試薬があります。例えば、4-クロロ-5-メトキシピリジン-2-甲...
全氟-1,2-二甲基環己烷を含む廃棄物はどのように処理すべきですか?
全氟-1,2-二甲基環己烷(CAS番号:306-98-9)の廃棄物は、特別な処理が必要です。まず、廃棄物を密閉容器に収集し、適切な防漏容器に保管します。次に、専...
3-(溴甲基)苯乙酸の主な用途は何ですか?
3-(溴甲基)苯乙酸は主に研究用化学薬品として利用され、有機合成や医薬品の開発に用いられます。また、特定の化合物の合成中間体としても使用されることがあります。
5-イドキド-4-メチオキシ-6-メチルピリミジニン-2-アミンはどのように保存すればよいですか?
5-イドキド-4-メチオキシ-6-メチルピリミジニン-2-アミンは冷暗所で密栓の容器に保存し、直射日光を避けて保管することをお勧めします。温度は常温とし、湿気を...
1-(2-溴-6-甲氧基苯基)乙酮を取り扱う際の実験室安全事項は何ですか?
実験室では、1-(2- Bromo-6-methoxyphenyl)ethanoneを取り扱う際には、ゴーグルや面具、手袋などのPPEを使用することが推奨されま...
5-(4,4,5,5-テトラメチル-1,3,2-ダイオキサボラロール-2-イル)-1,3-ジヒドロ-2-ベンゾフランは安全ですか?
5-(4,4,5,5-テトラメチル-1,3,2-ダイオキサボラロール-2-イル)-1,3-ジヒドロ-2-ベンゾフランは一般に安全ですが、取扱いには注意が必要です...
4-溴萘-1-甲酸の代替品はありますか?
4-溴萘-1-甲酸は比較的稀な化合物ですが、類似物としては、4-クロロ-1-ナフホリック酸やその他のブロモ置換ナフホリック酸が挙げられます。ただし、これらの代替...
ε-白藜芦醇脱氢二聚体の代替品はありますか?
ε-白藜芦醇脱氢二聚体の代替品としては、ε-白藜芦醇、ポリフェノール類、フラボノイド類が挙げられます。これらは類似の化学構造と生物学的活性を持っています。ただし...
掲載誌
Journal of Analytical Atomic Spectrometry

The Journal of Analytical Atomic Spectrometry (JAAS) is the central journal for publishing innovative research on fundamentals, instrumentation, and methods in the determination, speciation and isotopic analysis of (trace) elements within all fields of application. This includes, but is not restricted to, the most recent progress, developments and achievements in all forms of atomic and elemental detection, isotope ratio determination, molecular analysis, plasma-based analysis and X-ray techniques. The journal welcomes full papers, communications, technical notes, critical and tutorial review articles, editorials, and comments, in addition to the Atomic Spectrometry Updates (ASU) literature reviews that are prepared by an expert panel. Submissions are welcome in the following areas, but note this list reflects the current scope and authors are strongly encouraged to contact the Editorial team if they believe that their work offers potentially new and emerging research relevant to the journal remit: Fundamental studies in the following. New and existing sources for atomic emission, absorption, fluorescence and mass spectrometry and those that provide both atomic and molecular information Sample introduction techniques for solids, liquids, gases Improvements in sensitivity, selectivity, precision, accuracy and/or robustness Isotope ratio measurements, including techniques for improving precision and mass bias correction Single channel and multichannel simultaneous detection systems Chemometrics, statistics, calibration techniques and internal standardisation Theoretical and numerical modelling of fundamental processes related to all of the above methodologies Novel or improved methodologies in areas of application including, but not limited to the following. Biosciences, including elemental, speciation and isotopic analysis in biological systems, immunoassays based on metal-labeled antibodies, bio-imaging, and nanoparticle toxicology Geochemistry Environmental science Materials science, including engineered nanoparticles and quantum dots Metrology, including reference materials Forensic analysis Food and agricultural sciences Energy Archaeometry Molecular analysis. Molecular sources for elemental and isotopic analysis Atomic sources for molecular analysis Atomic and molecular techniques simultaneously used for complementary chemical information All contributions are judged on originality and quality of scientific content, and appropriateness of length to content of new science.












![Sodium (2Z)-7-{[(2R)-2-amino-2-carboxyethyl]sulfanyl}-2-({[(1S)-2,2-dimethylcyclopropyl]carbonyl}amino)-2-heptenoate structure Sodium (2Z)-7-{[(2R)-2-amino-2-carboxyethyl]sulfanyl}-2-({[(1S)-2,2-dimethylcyclopropyl]carbonyl}amino)-2-heptenoate structure](https://static.chemtradehub.com/structs/811/81129-83-1-441c.webp)

