Insight into the role of nitrogen in N-doped ordered mesoporous carbons for the spontaneous non-covalent attachment and electrografting of redox-active materials

文献情報

出版日 2023-02-17
DOI 10.1039/D3AN00176H
インパクトファクター 4.616
著者

Nasim Shamsvand, Hamzeh Hassanaki


原文を見る

要旨

The role of nitrogen functional groups in nitrogen-doped ordered mesoporous carbons (OMCs) toward the spontaneous non-covalent and electrografting was investigated using two home-made ionic liquid-derived ordered mesoporous carbons having different nitrogen concentrations (guanine-rich ionic liquid-derived ordered mesoporous carbon (GIOMC) and ionic liquid-derived ordered mesoporous carbon (IOMC)). The carbonaceous materials were fabricated by the carbonization of a mixture of ionic liquid (1-methyl-3-phenethyl-1H-imidazolium hydrogen sulfate) as a carbon source using SBA-15 as a hard template. Guanine was used during the carbonization of GIOMC as a nitrogen source. The electrode was modified with either GIOMC or IOMC followed by electrochemical surface functionalization with a few electro-active precursors as redox-active molecular models bearing different substituents and electronic properties. The high surface coverage of 5.6(±0.3) × 10−9 mol cm−2 for 4,4-biphenol was obtained for the GIOMC-modified electrode. We seek to explain whether the nitrogen content could indeed exert a dramatic impact on loading electroactive species on the electrode surface. The non-covalent anchoring studies indicated that at higher pH values the loading of electro-active moieties was significantly influenced by the content of nitrogen on the employed OMCs. The adsorption capacity (mg g−1) of the OMCs was studied for catechol as a typical electro-active species in the range of 0.050–0.165 mg ml−1. The adsorption capacity of 0.11 mg g−1 catechol was 42(±4) and 26(±3) mg g−1 for GIOMC and IOMC, respectively. In addition, our observations revealed that electro-grafting efficiency via diazonium ion was restricted by the protonation of nitrogen in the reaction media. Further, the fabricated redox-active/N-doped OMC electrodes showed sensitivity to pH, which was accompanied by either a Nernstian shift of the redox peak potentials (60(±3) mV per pH) in the pH range of 2–13 in the buffer solutions or variations of the redox peak currents (9.7(±0.3) μA per pH) in the pH range of 1–5.5 in the unbuffered situations. The resulting electrodes as voltammetric pH probes showed a simple response to pH in both buffer and unbuffered solutions. In addition, we introduced the fabricated electrode as a zero-gap generator/collector electrode system using a single electrode to recognize proton-dependent electron transfer from the proton-independent electrode process by detecting pH changes quite close to the surface of the electrode. The detailed descriptions are outlined.

関連文献

Strand displacement activated peroxidase activity of hemin for fluorescent DNA sensing

Quanbo Wang, Nan Xu, Zhen Gui, Jianping Lei, Huangxian Ju, Feng Yan

2015-08-07 Paper

DOI: 10.1039/C5AN01206F

Analysis of the lipid profiles in a section of bovine brain via non-catalytic rapid methylation

Jong-Min Jung, Ki-Hyun Kim, Eilhann E. Kwon, Hyung-Wook Kim

2015-07-29 Communication

DOI: 10.1039/C5AN00961H

Colorimetric and “turn-on” fluorescent determination of Cu2+ ions based on rhodamine–quinoline derivative

Liang Feng, Hui Li, Yongjun Lv, Yafeng Guan

2012-10-01 Paper

DOI: 10.1039/C2AN36215E

Front cover

Cover

DOI: 10.1039/C5AN90068A

Cellular discrimination using in vitro Raman micro spectroscopy: the role of the nucleolus

Z. Farhane, F. Bonnier, A. Casey, A. Maguire, L. O'Neill, H. J. Byrne

2015-07-20 Paper

DOI: 10.1039/C5AN01157D

Back cover

Cover

DOI: 10.1039/C5AN90070K

Aptamer carbon nanodot sandwich used for fluorescent detection of protein

Bailu Xu, Chuanqi Zhao, Weili Wei, Jinsong Ren, Daisuke Miyoshi, Naoki Sugimoto, Xiaogang Qu

2012-10-01 Communication

DOI: 10.1039/C2AN36174D

Simultaneous electroanalytical determination of hydroquinone and catechol in the presence of resorcinol at an SiO2/C electrode spin-coated with a thin film of Nb2O5

Thiago C. Canevari, Leliz T. Arenas, Richard Landers, Rogério Custodio, Yoshitaka Gushikem

2012-10-23 Paper

DOI: 10.1039/C2AN36170A

Determination of metal ion concentrations by SERS using 2,2′-bipyridyl complexes

Julie Docherty, Samuel Mabbott, W. Ewen Smith, John Reglinski, Karen Faulds, Christine Davidson, Duncan Graham

2015-08-21 Paper

DOI: 10.1039/C5AN01525A

こちらもおすすめ

化合物よくある質問

除水剤ALT-201は安全ですか?

除水剤ALT-201は一般的に安全ですが、避けるべきは皮膚や目への接触です。適切な防護具を着用し、安全基準を守ることが重要です。

28770-01-62-(2-Isopropyl-1,3-o...
化合物よくある質問

「邻羟基阿托伐他汀内酯标准品」に適用される法規ガイドelinesは何ですか?

CAS番号163217-74-1の「邻羟基阿托伐他汀内酯标准品」は、GHS分類では危険物に分類されず、主にREACH規則とFDA/EPAの管理対象となります。R...

163217-74-1ortho-Hydroxy Atorva...
化合物よくある質問

メチル(3R)-3-アミノ-2,3-ジヒドロ-1-ベンゾファンラニン-5-カルボイル酸塩塩酸塩の主な用途は何ですか?

メチル(3R)-3-アミノ-2,3-ジヒドロ-1-ベンゾファンラニン-5-カルボイル酸塩塩酸塩は、医薬品や合成化学の研究に広く用いられます。また、特定の薬物の前...

2241594-15-8Methyl (3R)-3-amino-...
化合物よくある質問

トランス-4-メチルピロリジン-3-オール塩酸塩はどのように合成されますか?

トランス-4-メチルピロリジン-3-オール塩酸塩は、4-メチルピロリジンの塩酸塩化によって合成されます。一般的な合成方法では、4-メチルピロリジンを塩酸に加えて...

265108-42-7trans-4-Methylpyrrol...
化合物よくある質問

硫雜環丁烷-1,1-二氧化物は安全ですか?

硫雜環丁烷-1,1-二氧化物は安全ではありません。毒性は報告されていませんが、高温下で分解し、可燃性があるため、高圧ガスは注意が必要です。密閉した容器で保管し、...

5687-92-3Thietane 1,1-dioxide
化合物よくある質問

ブラエリリンの主な用途は何ですか?

ブラエリリンは主に医薬品製造における薬物アドベリンの合成材料として使用されます。また、研究用途や化学合成材料としても広く利用されています。

6054-10-02H, 8H-Benzo[1,2-b
化合物よくある質問

9-ヒドロキシエリプチシネ塩酸塩はどのように合成されますか?

9-ヒドロキシエリプチシネ塩酸塩は、エリプチシネから塩酸を添加することで合成されます。選択性は高いですが、収率は約70%です。

52238-35-49-Hydroxyellipticine...
化合物よくある質問

5-塩素-2-(メチルアミノ)フェニル-(2-塩素フェニル)メタン酮の物理化学的性質は何ですか?

5-塩素-2-(メチルアミノ)フェニル-(2-塩素フェニル)メタン酮のCAS番号は5621-86-3です。この化合物は白色の結晶性粉末で、分子量は415.03で...

5621-86-3[5-Chloro-2-(methyla...
化合物よくある質問

1-[2-(4-甲氧基-苯氧基)-乙基]-哌嗪はどのように保存すればよいですか?

1-[2-(4-甲氧基-苯氧基)-乙基]-哌嗪は、直射日光を避けて暗所に、室温(15-25℃)で保管し、密閉容器に入れることで安定性を保つことができます。

117132-44-21-[2-(4-Methoxy-phen...
化合物よくある質問

2-[3-(4-甲氧基フェニル)プロピル]-4,4,5,5-四メチル-1,3,2-ドイボロロールアンの主な用途は何ですか?

2-[3-(4-甲氧基フェニル)プロピル]-4,4,5,5-四メチル-1,3,2-ドイボロロールアンは、医薬品の合成、有機合成化学、および新材料の研究で使用され...

1073371-72-82-[3-(4-Methoxypheny...

掲載誌

Analyst

Analyst
CiteScore: 7.8
自己引用率: 5.6%
年間論文数: 653

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.

おすすめ化合物

おすすめサプライヤー

免責事項
このページに表示される学術雑誌情報は、参考および研究目的のみを目的としています。当社は雑誌出版社とは提携しておらず、投稿の取り扱いも行っておりません。出版に関するお問い合わせは、各雑誌出版社に直接ご連絡ください。
表示されている情報に誤りがある場合は、support@chemtradehub.com までご連絡ください。迅速に確認し、対応いたします。