Molecularly imprinted nanoparticle-based assay (MINA) for microcystin-LR detection in water

文献情報

出版日 2022-12-14
DOI 10.1039/D2AN01680J
インパクトファクター 4.616
著者

Yadiris García, Myleidi Vera, Verónica A. Jiménez, Luis F. Barraza, Joao Aguilar, Susana Sánchez, Eduardo D. Pereira


原文を見る

要旨

Microcystins (MCs) are highly toxic peptides produced by cyanobacteria during algal blooms. Microcystin-leucine-arginine (MC-LR) is the most toxic and common MC variant with major effects on human and animal health upon exposure. MC-LR detection has become critical to ensure water safety, therefore robust and reliable analytical methods are needed. This work reports the development of a simple and optimized Molecularly Imprinted Nanoparticle-Based Assay (MINA) for MC-LR detection in water. Molecularly Imprinted Nanoparticles (MINs) were prepared by solid-phase polymerization on glass beads conjugated to MC-LR through (3-aminopropyl) triethoxysilane (APTES) via amide bonding. APTES-modified glass beads were obtained under optimized conditions to maximize the density of surface amino groups available for MC-LR conjugation. Two quinary mixtures of acrylic monomers differing in charge, polarity, and functionality were selected from molecular docking calculations and used to obtain MINs for MC-LR recognition using N,N′-methylene-bis-acrylamide (BIS) as the crosslinking agent. MINs were immobilized by physical adsorption onto 96-well polystyrene microplate and evaluated as per their rebinding capacity toward the analyte by using a covalent conjugate between MC-LR and the enzyme horseradish peroxidase (HRP). Experimental conditions for the MINs immobilization protocol, HRP-MC-LR concentration, and composition of the blocking solution were set to maximize the colorimetric response of the MINs compared to non-treated wells. Optimized conditions were then applied to conduct competitive MINAs with the HRP-MC-LR conjugate and the free analyte, which confirmed the preferential binding of MC-LR to the immobilized MINs for analyte concentrations ranging from 1 × 10−5 nmol L−1 to 100 nmol L−1. The best competitive MINA showed a limit of detection of 2.49 × 10−4 nmol L−1 and coefficients of variation less than 10% (n = 6), which are auspicious for the use of MINs as analytical tools for MC-LR detection below the permissible limits issued by WHO for safe water consumption (1.00 nmol L−1). This assay also proved to be selective to the analyte in cross-reactivity studies with two analogous microcystins (MC-RR and MC-YR). Analyses of lagoon and drinking water samples enriched with MC-LR revealed strong matrix effects that reduce the MINA response to the analyte, thus suggesting the need for sample pretreatment methods in future development in this subject.

関連文献

The rediscovery of Alfred Werner's second hexol

W. Gregory Jackson, Josephine A. McKeon, Margareta Zehnder, Markus Neuberger, Silvio Fallab

2004-09-06 Communication

DOI: 10.1039/B408277J

Shuttling through reversible covalent chemistry

David A. Leigh, Emilio M. Pérez

2004-09-23 Communication

DOI: 10.1039/B412570C

Silicon-assisted propargylic transfer to aldehydes

Kiew-Ching Lee, Man-Jing Lin, Teck-Peng Loh

2004-09-21 Communication

DOI: 10.1039/B411653D

Crystal engineering of urea α-network via I⋯O2N synthon and design of SHG active crystal N-4-iodophenyl-N′-4′-nitrophenylurea

Sumod George, Ashwini Nangia, Chi-Keung Lam, Thomas C. W. Mak, Jean-François Nicoud

2004-04-20 Communication

DOI: 10.1039/B402050B

Encapsulation of gases in the solid state

Alexander V. Leontiev, Dmitry M. Rudkevich

2004-06-01 Communication

DOI: 10.1039/B402997F

Superhydrophobic silica aerogels by fluorination at the gel stage

Anna Roig, Elies Molins, Elisenda Rodríguez, Sandra Martínez, Marcial Moreno-Mañas, Adelina Vallribera

2004-09-06 Communication

DOI: 10.1039/B407987F

Direct conversion of iron stearate into magnetic Fe and Fe3C nanocrystals encapsulated in polyhedral graphite cages

Junfeng Geng, David A. Jefferson, Brian F. G. Johnson

2004-09-21 Communication

DOI: 10.1039/B406227B

A novel fluoride sensor based on fluorescence enhancement

Guoxiang Xu, Matthew A. Tarr

2004-04-02 Communication

DOI: 10.1039/B316121H

A novel 2D net-like supramolecular polymer constructed from Ln6Cu24 node and trans-Cu(Gly)2 bridge

Jian-Jun Zhang, Sheng-Qing Xia, Tian-Lu Sheng, Sheng-Min Hu, Guido Leibeling, Franc Meyer, Xin-Tao Wu, Sheng-Chang Xiang, Rui-Biao Fu

2004-04-14 Communication

DOI: 10.1039/B400447G

こちらもおすすめ

化合物よくある質問

2,3-スチオエポキシマドルを取り扱う際の実験室安全事項は何ですか?

取り扱いにはPPE(プロテクティブ・パーソナル・エイド)が必要で、防ぐ手袋と保護眼鏡を着用してください。ドラフトチャンバーの使用を推奨します。漏洩した場合は、適...

4267-80-52,3-Thioepoxy Madol
化合物よくある質問

6-氟-2-氨基苯酚の主な用途は何ですか?

6-氟-2-氨基苯酚は主に医薬品の合成材料として使用され、一部の農薬の製造にも利用されます。また、研究用途でも広く使用されています。

53981-25-22-Amino-6-fluorophen...
化合物よくある質問

BOC-S-3-アミニ-4-(4-メチオキシベンチル)-ブタン酸の代替品はありますか?

この化合物の代替品としては、BOC保護基を有さないアミノ酸やその他の保護基化合物が考えられます。また、メチオキシ基を有しない他の芳香族アミノ酸も代替品として挙げ...

126800-59-7(3S)-4-(4-Methoxyphe...
化合物よくある質問

Methyl 2-(chloromethyl)-3-nitrobenzoate(1218910-61-2)の代替品はありますか?

Methyl 2-(chloromethyl)-3-nitrobenzoate(1218910-61-2)の代替品としては、化学組成を変えることで効果を達成する...

1218910-61-2Methyl 2-(chlorometh...
化合物よくある質問

(2R)-2-アミノ-N-ベンジル-3-ヒドロキシプロパナミドを含む廃棄物はどのように処理すべきですか?

(2R)-2-アミノ-N-ベンジル-3-ヒドロキシプロパナミドを含む廃棄物は、適切な廃棄物管理ガイドラインに基づき処理する必要があります。まず、廃棄物を適切に収...

175481-39-7(2R)-2-amino-N-benzy...
化合物よくある質問

6,7-二氢-咪唑並[1,2-a]ピリドイン-8(5h)-酮はどのように合成されますか?

6,7-二氢-咪唑並[1,2-a]ピリドイン-8(5h)-酮は、2-ブロモフェニルアセトインとリン酸ハロゲン化物を反応させることで合成できます。この反応は高温で...

457949-09-66,7-Dihydroimidazo[1...
化合物よくある質問

エチル(3R)-3-ピロリジニル酢酸水和塩とは何ですか?

エチル(3R)-3-ピロリジニル酢酸水和塩は、CAS番号1332459-32-1の化合物で、(R)-乙基2-(ピロリジン-3-基)酢酸塩水和塩と呼ばれます。この...

1332459-32-1Ethyl (3R)-3-pyrroli...
化合物よくある質問

(2S)-{[(2-メチルエチルオキシ]カルボニル}アミノ)[2-(トリアフルオロメチルフェニル]エチカシック酸の物理化学的性質は何ですか?

(2S)-{[(2-メチルエチルオキシ]カルボニル}アミノ)[2-(トリアフルオロメチルフェニル]エチカシック酸のCAS番号は1203454-45-8です。この...

1203454-45-8(2S)-({[(2-Methyl-2-...
化合物よくある質問

2-ブロモ-1-(2-メチル-2-プロパニル)-4-ニトロベンゼンはどのように保存すればよいですか?

2-ブロモ-1-(2-メチル-2-プロパニル)-4-ニトロベンゼンは、直射日光を避けて暗所で、室温(約15℃〜25℃)、乾燥した場所に保存する必要があります。ま...

6310-17-42-Bromo-1-(2-methyl-...
化合物よくある質問

1-[(4-硝基フェニル)スルホニル]-1H-1,2,4-三唑の市場動向や研究トレンドはどうですか?

市場動向としては、1-[(4-硝基フェニル)スルホニル]-1H-1,2,4-三唑は主に農業用除草剤や合成化学製品の原料として利用されています。研究トレンドとして...

57777-84-11-[(4-Nitrophenyl)su...

掲載誌

Analyst

Analyst
CiteScore: 7.8
自己引用率: 5.6%
年間論文数: 653

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.

おすすめサプライヤー

免責事項
このページに表示される学術雑誌情報は、参考および研究目的のみを目的としています。当社は雑誌出版社とは提携しておらず、投稿の取り扱いも行っておりません。出版に関するお問い合わせは、各雑誌出版社に直接ご連絡ください。
表示されている情報に誤りがある場合は、support@chemtradehub.com までご連絡ください。迅速に確認し、対応いたします。