Smartphone-imaged microfluidic biochip for measuring CD64 expression from whole blood

文献情報

出版日 2019-05-10
DOI 10.1039/C9AN00532C
インパクトファクター 4.616
著者

Hatice Ceylan Koydemir, Gregory L. Damhorst, Umer Hassan


原文を見る

要旨

Sepsis, a life-threatening syndrome that contributes to millions of deaths annually worldwide, represents a moral and economic burden to the healthcare system. Although no single, or even a combination of biomarkers has been validated for the diagnosis of sepsis, multiple studies have shown the high specificity of CD64 expression on neutrophils (nCD64) to sepsis. The analysis of elevated nCD64 in the first 2–6 hours after infection during the pro-inflammatory stage could significantly contribute to early sepsis diagnosis. Therefore, a rapid and automated device to periodically measure nCD64 expression at the point-of-care (POC) could lead to timely medical intervention and reduced mortality rates. Current accepted technologies for measuring nCD64 expression, such as flow cytometry, require manual sample preparation and long incubation times. For POC applications, however, the technology should be able to measure nCD64 expression with little to no sample preparation. In this paper, we demonstrate a smartphone-imaged microfluidic biochip for detecting nCD64 expression in under 50 min. In our assay, first unprocessed whole blood is injected into a capture chamber to immunologically capture nCD64 along a staggered array of pillars, which were previously functionalized with an antibody against CD64. Then, an image of the capture channel is taken using a smartphone-based microscope. This image is used to measure the cumulative fraction of captured cells (γ) as a function of length in the channel. During the image analysis, a statistical model is fitted to γ in order to extract the probability of capture of neutrophils per collision with a pillar (ε). The fitting shows a strong correlation with nCD64 expression measured using flow cytometry (R2 = 0.82). Finally, the applicability of the device to sepsis was demonstrated by analyzing nCD64 from 8 patients (37 blood samples analyzed) along the time they were admitted to the hospital. Results from this analysis, obtained using the smartphone-imaged microfluidic biochip were compared with flow cytometry. Again, a correlation coefficient R2 = 0.82 (slope = 0.99) was obtained demonstrating a good linear correlation between the two techniques. Deployment of this technology in ICU could significantly enhance patient care worldwide.

関連文献

Hot off the press

Hot off the Press Article

DOI: 10.1039/A806HOPY

Index pages

Paper

DOI: 10.1039/NP98603000I1

Hot off the press

Paper

DOI: 10.1039/A003HOPY

Glossary of abbreviations

Other

DOI: 10.1039/JA988030254R

Contents pages

Other

DOI: 10.1039/NP98805FP005

Medicinal Chemistry Principles and Practice, Second Edition

2003-03-03 Book Review

DOI: 10.1039/B301927F

Hot off the press

2001-11-07 Hot off the Press Article

DOI: 10.1039/B109453J

Editorial

2004-01-14 Editorial

DOI: 10.1039/B316155M

Hot off the press

2004-07-15 Hot off the Press Article

DOI: 10.1039/B410028J

Atomic Spectrometry Update—Environmental Analysis

Review Article

DOI: 10.1039/JA989040001R

こちらもおすすめ

化合物よくある質問

3-(5-フェニル-2-ファイル)-プロパン酸の市場動向や研究トレンドはどうですか?

この化合物の市場動向は不明ですが、類似化合物の需要は化学繊維、医薬品、農薬分野で安定しています。研究トレンドとしては、該当化合物の生物学的活性の評価や、その他の...

3465-61-03-(5-Phenyl-2-furyl)...
化合物よくある質問

3- Chloro-1H-indazol-5-olはどのように保存すればよいですか?

3- チロロ-1H-吲唑-5-醇は遮光し、直射日光を避けて、温度は室温を推奨し、密閉容器に保存してください。

885519-34-63-Chloro-1H-indazol-...
化合物よくある質問

二茂鐵是安全的吗?

二茂鐵在使用时需要谨慎,因为它具有一定的刺激性。在操作时应佩戴防护眼镜和手套,保持通风良好的环境,并避免皮肤接触和吸入。

849924-76-11,2,3,4,5-Cyclopenta...
化合物よくある質問

L-(1-~13~C)メチオニンの市場動向や研究トレンドはどうですか?

L-(1-~13~C)メチオニンは、医薬品やバイオテクノロジー分野での研究が増加しており、その価格は安定しています。新興研究分野では、代謝解析や遺伝子機能解析で...

81202-04-2L-(1-~13~C)Methionin...
化合物よくある質問

1,3-フェニレンビスメチレンビスアクリレートは安全ですか?

1,3-フェニレンビスメチレンビスアクリレートは一般的に安全ですが、直接皮膚に触れる場合は保護用具を使用することを推奨します。高濃度の蒸気が吸入された場合は呼吸...

22757-16-01,3-Phenylenebis(met...
化合物よくある質問

丹参醇Aはどのように保存すればよいですか?

丹参醇Aは、直射日光を避けて室温で保存し、密栓容器に入れることをお勧めします。適切な保存条件は、安定性を保ち、安全性を確保する上で重要です。

189308-08-5Danshenol A
化合物よくある質問

4-メチル-2-(1,1,1-三フロロ-2-メチルプロパニル)ピリドインとは何ですか?

CAS番号1378865-93-0の4-メチル-2-(1,1,1-三フロロ-2-メチルプロパニル)ピリドインは、合成化学分野で用いられる有機化合物の一種です。こ...

1378865-93-04-Methyl-2-(1,1,1-tr...
化合物よくある質問

N-フェニルベンジル-2-クロロ酢氨を取り扱う際の実験室安全事項は何ですか?

N-フェニルベンジル-2-クロロ酢氨は毒性があり、皮膚や粘膜に刺激を与えます。取り扱う際には、保護眼鏡、手袋、ゴーグルを着用することを強く推奨します。ドラフトチ...

2653-14-7N-benzyl-2-chloro-N-...
化合物よくある質問

UCN-02を取り扱う際の実験室安全事項は何ですか?

UCN-02は毒性は低いですが、人体への直接的な接触は避けるべきです。PPE要件はグローブと顔面保護具を着用することです。ドラフトチャンバーを使用して漏洩を処理...

化合物よくある質問

N-[3-[2-(二甲基氨基)乙氧基]-4-甲氧基苯基]-2'-甲基-4'-(5-甲基-1,2,4-恶二唑-3-基)-[1,1'-联苯]-4-甲酰胺を取り扱う際の実験室安全事項は何ですか?

手袋と保護眼鏡を着用し、漏洩時には吸気防止装置を使用してください。室温、乾燥した場所に保管し、直日光から隔離してください。SDS(安全データシート)を参照してく...

170230-39-4N-{3-[2-(Dimethylami...

掲載誌

Analyst

Analyst
CiteScore: 7.8
自己引用率: 5.6%
年間論文数: 653

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.

おすすめサプライヤー

免責事項
このページに表示される学術雑誌情報は、参考および研究目的のみを目的としています。当社は雑誌出版社とは提携しておらず、投稿の取り扱いも行っておりません。出版に関するお問い合わせは、各雑誌出版社に直接ご連絡ください。
表示されている情報に誤りがある場合は、support@chemtradehub.com までご連絡ください。迅速に確認し、対応いたします。