A two-photon ratiometric fluorescent probe for highly selective sensing of mitochondrial cysteine in live cells
文献情報
Li Fan, Wenjia Zhang, Xiaodong Wang, Wenjuan Dong, Yaoli Tong, Chuan Dong, Shaomin Shuang
We report herein a two-photon ratiometric fluorescent probe (DNEPI) for mitochondrial cysteine (Cys) detection on the basis of a merocyanine (compound 1) as the two-photon fluorophore and a 2,4-dinitrobenzensulfonyl (DNBS) unit as the biothiol reaction site. Upon reaction with Cys in DMSO/PBS (1/1, v/v), DNEPI showed a distinct ratiometric fluorescence emission characteristic (F583 nm/F485 nm) linearly proportional to Cys concentrations over the range of 2–10 μM, which was attribute to the enhanced intramolecular charge transfer (ICT) effect by cleavage of the sulfonic acid ester bond of DNEPI to release compound 1. More importantly, the probe could detect Cys with a fast response time (within 2 min) and the detection limit was quantitatively calculated as 0.29 μM. Furthermore, DNEPI not only exhibited high selectivity toward Cys over other similar biothiols, including homocysteine (Hcy) and glutathione (GSH), but also displayed significant mitochondrial-targeting ability, which were favorable for mitochondrial Cys-selective imaging. Subsequently, application of DNEPI to Cys imaging in live cells was successfully achieved by two-photon fluorescence microscopy, suggesting that the probe proposed here could be used to monitor mitochondrial Cys concentration changes in live cells with negligible interference from other biological thiols.
関連文献
A theoretical study on the structures and electronic and magnetic properties of new boron nitride composite nanosystems by depositing superhalogen Al13 on the surface of nanosheets/nanoribbons
Xiaopeng Shen, Guangtao Yu, Chenghui Zhang, Ting Wang, Xuri Huang, Wei Chen
DOI: 10.1039/C8CP00015H
Oxide–organic heterostructures: a case study of charge transfer disturbance at a SnO2–copper phthalocyanine buried interface
Lucyna Grządziel, Paulina Powroźnik, Monika Kwoka, Julian Rechmann
DOI: 10.1039/C8CP01976B
The effect of solvation and temperature on the adsorption of small organic molecules on calcite
A. Budi, S. L. S. Stipp, M. P. Andersson
DOI: 10.1039/C7CP06747J
Study of oxygen evolution reaction on amorphous Au13@Ni120P50 nanocluster
Yanzhou Wang, Panpan Gao, Xiaoxu Wang, Jinrong Huo, Lu Li, Yajing Zhang, Alex A. Volinsky, Ping Qian, Yanjing Su
DOI: 10.1039/C8CP00784E
Effective interaction potentials for model amphiphilic surfactants adsorbed at fluid–fluid interfaces
Ahmad Moghimikheirabadi, Patrick Ilg
DOI: 10.1039/C8CP01632A
Hydrocarbon decomposition kinetics on the Ir(111) surface
H. Tetlow, D. Curcio, L. Kantorovich
DOI: 10.1039/C7CP07526J
Assessing AMBER force fields for protein folding in an implicit solvent
Qiang Shao, Weiliang Zhu
DOI: 10.1039/C7CP08010G
Cluster assemblies as superatomic solids: a first principles study of bonding & electronic structure
Nicola Gaston
DOI: 10.1039/C7CP06755K
First-principles method for calculating the rate constants of internal-conversion and intersystem-crossing transitions
V. N. Cherepanov, D. Sundholm
DOI: 10.1039/C7CP08703A
こちらもおすすめ
(S)-四氢呋喃-3-羧酸の物理化学的性質は何ですか?
CAS番号168395-26-4の(S)-四氢呋喃-3-羧酸は、白色の結晶が特徴的な性質を持ちます。分子量は128.08であり、水に溶けやすく、アルコールなど...
塩基性硫黄化合物1,3-ジメチル-1-[5-(三氟甲基)-1,3,4-硫杂环己二酮-2-基]尿素を含む廃棄物はどのように処理すべきですか?
塩基性硫黄化合物1,3-ジメチル-1-[5-(三氟甲基)-1,3,4-硫杂环己二酮-2-基]尿素を含む廃棄物は、専門的な廃棄処理施設で焼却処理を行うべきです。ま...
インドリジン-2-カルボン酸は安全ですか?
インドリジン-2-カルボン酸は一般的に安全ですが、過度に濃い状態では刺激性があります。取り扱いには適切な防護具を使用し、直接触れや吸入を避ける必要があります。
5-甲基-2-(3-ピリジニル)-1,3-テイゾール-4-オールの市場動向や研究トレンドはどうですか?
5-甲基-2-(3-ピリジニル)-1,3-テイゾール-4-オールは、医薬品や農薬、および合成化学の分野において研究が進められています。市場動向としては、化学物質...
4,4',4''-(嘧啶-2,4,6-三基)三苯甲醛はどのように保存すればよいですか?
4,4',4''-(嘧啶-2,4,6-三基)三苯甲醛は、密閉容器に保管し、避けておくことが重要です。室温で保管し、直射日光を避けてください。
(3aR)-1,3,3-トリフェニルテトラヒドロ-3H-ピロロ[1,2-c][1,3,2]-オキザボロロールについて、適用される法規ガイドラインは何ですか?
(3aR)-1,3,3-トリフェニルテトラヒドロ-3H-ピロロ[1,2-c][1,3,2]-オキザボロロールは、GHS(国際危険物識別ルール)の分類が適用されま...
6-(4-氯苯氧基)吡啶-3-胺の代替品はありますか?
6-(4-氯苯氧基)吡啶-3-胺の代替品としては、他の芳香族アミン化合物や類似の除草剤が考えられます。ただし、他の化合物と同様に、代替品の選択には安全性と効果性...
3-フェニル-3,4-ジヒドロ-2H-1,4-ベンゾキサジンを取り扱う際の実験室安全事項は何ですか?
3-フェニル-3,4-ジヒドロ-2H-1,4-ベンゾキサジンを取り扱う際は、防塵マスク、ゴーグル、ゴム手袋を使用し、ドラフトチャンバー内で作業することを推奨しま...
掲載誌
Analyst

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.










![9H-Fluoren-9-ylmethyl [(2S)-1-hydroxy-3-(1H-indol-3-yl)-2-propanyl]carbamate structure 9H-Fluoren-9-ylmethyl [(2S)-1-hydroxy-3-(1H-indol-3-yl)-2-propanyl]carbamate structure](https://static.chemtradehub.com/structs/153/153815-60-2-a67d.webp)