A pressure-driven gas-diffusion/permeation micropump for self-activated sample transport in an extreme micro-environment
文献情報
The micropump is the most important functional unit of a micro total analysis system (μTAS). An ideal microfluidics system should adopt simple, stable, robust, inexpensive, and integrated on-chip strategies to transport samples for downstream applications, with little or no external energy consumption and limited manual intervention. Nevertheless, it remains a key challenge for traditional micropumps to be directly integrated into self-contained and disposable μTAS for velocity-stable and passive sample transport. The best way to assess the capability of passive micropumps is to evaluate their pumping performance in extreme environments, e.g. a 3D configurated microchannel instead of a 2D configuration, high temperature conditions instead of at room temperature, a long microchannel instead of short microchannel, a complex topological microsystem (e.g. a microvascular network interconnecting multiple inlets and outlets) instead of a simple topological microsystem (e.g. a one-directional microchannel connecting only one inlet and one outlet), and multi-phase microdroplet transport instead of single-phase plug transport. In this review, a novel micropumping methodology – a pressure-driven gas-diffusion/permeation micropump – is described, which is the first review paper dedicated to this subject. A comprehensive overview is provided for comparison between this novel micropumping methodology and traditional passive micropumps, especially for applications in stable velocity control in the aforementioned extreme environments. Compared with mainstream conventional micropumps, we confirm that pressure-driven gas-diffusion/permeation micropumps combine a number of superior properties all into one device, such as small size, simple structure, without the need for microfabrication procedures or external power consumption, strong transport capacity, homogeneous flow velocity, delivery capacity for both multi-phase microdroplets and single-phase plugs, long-distance transport, persistent pumping for both 3D microchannels and complex topological microsystems (e.g. a biomimetic microvasculature), low cost, ease of microdevice integration, bubble suppression and amazing stability at high temperatures. An advanced outlook and perspectives for the future development of this novel micropump are also discussed, which may serve as a starting point for researchers in the microfluidics fields to harness pressure-driven gas-diffusion/permeation micropumps for downstream applications.
関連文献
Interpretation of experimental hydrogen-bond enthalpies and entropies from COSMO polarisation charge densities
Jens Reinisch, Frank Eckert, Jérôme Graton, Jean-Yves Le Questel
DOI: 10.1039/C3CP44611E
Hydrogen and carbon monoxide generation from laser-induced graphitized nanodiamonds in water
Dong Myung Jang, Hyung Soon Im, Yoon Myung, Yong Jae Cho, Han Sung Kim, Seung Hyuk Back, Jeunghee Park, Eun Hee Cha, Minyung Lee
DOI: 10.1039/C3CP50769F
Thermodynamics of oligomer formation: implications for secondary organic aerosol formation and reactivity
Joseph W. DePalma, Andrew J. Horan, Wiley A. Hall IV, Murray V. Johnston
DOI: 10.1039/C3CP44586K
Probing micro-solvation in “numbers”: the case of neutral dipeptides in water
Panteleimon G. Takis, Konstantinos D. Papavasileiou, Loukas D. Peristeras, Vasilios S. Melissas, Anastassios N. Troganis
DOI: 10.1039/C3CP44606A
Photoelectrical properties and the electronic structure of Tl1−xIn1−xSnxSe2 (x = 0, 0.1, 0.2, 0.25) single crystalline alloys
G. E. Davydyuk, H. Kamarudin, G. L. Myronchuk, S. P. Danylchuk, A. O. Fedorchuk, L. V. Piskach, M. Yu. Mozolyuk, O. V. Parasyuk
DOI: 10.1039/C3CP50836F
Computing vibrational spectra from ab initio molecular dynamics
Martin Thomas, Martin Brehm, Reinhold Fligg, Peter Vöhringer, Barbara Kirchner
DOI: 10.1039/C3CP44302G
A statistical approach for analyzing the development of 1H multiple-quantum coherence in solids
Yuuki Mogami, Yasuto Noda, Hiroto Ishikawa, K. Takegoshi
DOI: 10.1039/C3CP43778G
Photoinduced energy and charge transfer in a p-phenylene-linked dyad of boron dipyrromethene and monostyryl boron dipyrromethene
Roel Menting, Jian-Yong Liu, Ying-Si Huang, Dennis K. P. Ng, Beate Röder
DOI: 10.1039/C3CP50576F
Analysis of visible-light-active Sn(ii)–TiO2 photocatalysts
Venkata Bharat Ram Boppana, Feng Jiao, Dave Newby, Jr., Jude Laverock, Kevin E. Smith, Jean Claude Jumas, Greg Hutchings, Raul F. Lobo
DOI: 10.1039/C3CP44635B
こちらもおすすめ
3-イチチルビフェニルはどのように合成されますか?
3-イチチルビフェニルは、ビフェニルとイチプロピオニトリルを回収率約90%で反応させて合成されます。触媒は通常、亜リチウムホウ素を用います。
8-溴-5-三氟甲基喹啉はどのように合成されますか?
8-溴-5-三氟甲基喹啉は、5-トリフルオロメチル-2-メチル-1,3-ベンゼンジオールをブロモエタノールと反応させて生成します。この反応は塩基性条件下で行われ...
ジメチル4-(4,4,5,5-テトラメチル-1,3,2-ドioxaborolan-2-基)-2,6-ピリジンジカルボイル酸フェニルアミニドの代替品はありますか?
ジメチル4-(4,4,5,5-テトラメチル-1,3,2-ドioxaborolan-2-基)-2,6-ピリジンジカルボイル酸フェニルアミニドの代替品としては、4-...
N-(3,5-ヘキサクロロ-4-ピリドインイル)-8-メチオキシ-5-キノリンカーボン酸の市場動向や研究トレンドはどのようなものでしょうか?
N-(3,5-ヘキサクロロ-4-ピリドインイル)-8-メチオキシ-5-キノリンカーボン酸の市場動向は、主に産業用途での需要により影響を受けます。研究トレンドとし...
イソステアロイルグリセリルは安全ですか?
イソステアロイルグリセリルは一般的に安全性が高いとされていますが、過度な使用や個人差により皮�owsん炎などの反応が起こる可能性があります。使用前に医師に相談す...
1-(二苯甲基)-3,3-二氟-氮杂环丁烷の市場動向や研究トレンドはどうですか?
1-(二苯甲基)-3,3-二氟-氮杂环丁烷の市場動向は、医薬品や合成化学の研究分野で注目を集めています。新興研究は、該当化合物の合成改良と生体内での作用メカニズ...
3-チオフェンスチオールの物理化学的性質は何ですか?
3-チオフェンスチオールのCAS番号は7774-73-4です。結晶性の白色粉末で、分子量は122.17です。この化合物は水に微溶解し、エタノールやジクロロメタン...
2-Methyl-2-propanyl (2S)-2-(aminomethyl)-1-piperidinecarboxylateは安全ですか?
2-Methyl-2-propanyl (2S)-2-(aminomethyl)-1-piperidinecarboxylateは一定の安全性基準を満たしていま...
CAS番号1316822-90-8の化合物は安全ですか?
CAS番号1316822-90-8の化合物は安全性に関しては評価が不足していますが、一般的には生物学的に活性な物質であり、取り扱いには適切な安全防護措置が必要で...
Tert-butyl 2-(2-羟基乙基)哌嗪-1-羧酸はどのように保存すればよいですか?
Tert-butyl 2-(2-羟基乙基)哌嗪-1-羧酸は、冷暗所で保存し、直射日光から遠ざけてください。容器は密閉し、高湿度や高温を避けて保管してください。
掲載誌
Analyst

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.














