Poly(2-cycloalkyl-2-oxazoline)s: high melting temperature polymers solely based on Debye and Keesom van der Waals interactions
文献情報
Kathleen Lava, Bart Verbraeken, Richard Hoogenboom
The synthesis of new 2-cycloalkyl-2-oxazoline monomers, namely 2-cyclobutyl (cBuOx), 2-cyclopentyl (cPentOx) and 2-cyclohexyl-2-oxazoline (cHexOx) is described. Their microwave-assisted cationic ring-opening polymerisation allowed the synthesis of well-defined homopolymers. The resulting homopolymers are crystalline and have high chemical resistance to organic solvents. The highest melting point was registered for cPentOx (306 °C), followed by cHexOx (251 °C) and cBuOx (243 °C). The crystal structure of the homopolymers was put into evidence by X-ray diffraction and appeared to be similar to that of the poly(2-isopropyl-2-oxazoline). The absence of any hydrogen bonding or π–π interactions, makes these compounds a special class of high performance polymers which possess high Tm solely based on Debye and Keesom van der Waals interactions of the side-chains. The copolymerization of cPentOx with 2-ethyl-2-oxazoline (EtOx) and cBuOx, respectively are also reported indicating the formation of near ideal random copolymers. Furthermore, the copolymers of cPentOx with cBuOx with compositions in the range from 0 to 100% revealed a linear dependence of melting temperature with the weight fraction of comonomer. For cPentOx-EtOx copolymers containing up to 25 wt% EtOx a linear decrease of the melting temperature with composition was registered, most likely due to the disturbance of the cPentOx crystalline domains. Further, increasing the EtOx wt% revealed a complex non-linear dependence of glass transition temperature on composition, whereby the glass transition temperature of some copolymers was lower than for pure PEtOx.
関連文献
High throughput volatile fatty acid skin metabolite profiling by thermal desorption secondary electrospray ionisation mass spectrometry
Helen J. Martin, James C. Reynolds, Svetlana Riazanskaia, C. L. Paul Thomas
DOI: 10.1039/C4AN00134F
Indirect determination of dissolved silicate in surface water using energy-dispersive X-ray fluorescence spectrometry
Katarzyna Pytlakowska, Marzena Dabioch, Rafal Sitko
DOI: 10.1039/C4AN00414K
Reagentless uric acid biosensor based on Ni microdiscs-loaded NiO thin film matrix
Kashima Arora, Monika Tomar, Vinay Gupta
DOI: 10.1039/C4AN01029A
3-Aminophenylboronic acid-functionalized CuInS2 quantum dots as a near-infrared fluorescence probe for the detection of dicyandiamide
Siyu Liu, Shu Pang, Hui Huang, Xingguang Su
DOI: 10.1039/C4AN01065E
Ultrasensitive colorimetric carcinoembryonic antigen biosensor based on hyperbranched rolling circle amplification
Kai Liang, Shuiting Zhai, Zhidong Zhang, Xiaoyang Fu, Jingwei Shao, Zhenyu Lin, Bin Qiu, Guo-nan Chen
DOI: 10.1039/C4AN00417E
Redox cycling without reference electrodes
Sahana Sarkar, Klaus Mathwig, Shuo Kang, Ab. F. Nieuwenhuis, Serge G. Lemay
DOI: 10.1039/C4AN01287A
Detection of c-reactive protein based on a magnetic immunoassay by using functional magnetic and fluorescent nanoparticles in microplates
S. F. Yang, B. Z. Gao, C. Bor Fuh
DOI: 10.1039/C4AN00921E
Electrochemical quantification of iodide ions in synthetic urine using silver nanoparticles: a proof-of-concept
Her Shuang Toh, Kristina Tschulik, Christopher Batchelor-McAuley, Richard G. Compton
DOI: 10.1039/C4AN00741G
Affinity-based precipitation via a bivalent peptidic hapten for the purification of monoclonal antibodies
Michael W. Handlogten, Jared F. Stefanick, Peter E. Deak
DOI: 10.1039/C4AN00780H
こちらもおすすめ
3-(5-フェニル-2-ファイル)-プロパン酸の市場動向や研究トレンドはどうですか?
この化合物の市場動向は不明ですが、類似化合物の需要は化学繊維、医薬品、農薬分野で安定しています。研究トレンドとしては、該当化合物の生物学的活性の評価や、その他の...
3- Chloro-1H-indazol-5-olはどのように保存すればよいですか?
3- チロロ-1H-吲唑-5-醇は遮光し、直射日光を避けて、温度は室温を推奨し、密閉容器に保存してください。
L-(1-~13~C)メチオニンの市場動向や研究トレンドはどうですか?
L-(1-~13~C)メチオニンは、医薬品やバイオテクノロジー分野での研究が増加しており、その価格は安定しています。新興研究分野では、代謝解析や遺伝子機能解析で...
1,3-フェニレンビスメチレンビスアクリレートは安全ですか?
1,3-フェニレンビスメチレンビスアクリレートは一般的に安全ですが、直接皮膚に触れる場合は保護用具を使用することを推奨します。高濃度の蒸気が吸入された場合は呼吸...
丹参醇Aはどのように保存すればよいですか?
丹参醇Aは、直射日光を避けて室温で保存し、密栓容器に入れることをお勧めします。適切な保存条件は、安定性を保ち、安全性を確保する上で重要です。
4-メチル-2-(1,1,1-三フロロ-2-メチルプロパニル)ピリドインとは何ですか?
CAS番号1378865-93-0の4-メチル-2-(1,1,1-三フロロ-2-メチルプロパニル)ピリドインは、合成化学分野で用いられる有機化合物の一種です。こ...
N-フェニルベンジル-2-クロロ酢氨を取り扱う際の実験室安全事項は何ですか?
N-フェニルベンジル-2-クロロ酢氨は毒性があり、皮膚や粘膜に刺激を与えます。取り扱う際には、保護眼鏡、手袋、ゴーグルを着用することを強く推奨します。ドラフトチ...
UCN-02を取り扱う際の実験室安全事項は何ですか?
UCN-02は毒性は低いですが、人体への直接的な接触は避けるべきです。PPE要件はグローブと顔面保護具を着用することです。ドラフトチャンバーを使用して漏洩を処理...
N-[3-[2-(二甲基氨基)乙氧基]-4-甲氧基苯基]-2'-甲基-4'-(5-甲基-1,2,4-恶二唑-3-基)-[1,1'-联苯]-4-甲酰胺を取り扱う際の実験室安全事項は何ですか?
手袋と保護眼鏡を着用し、漏洩時には吸気防止装置を使用してください。室温、乾燥した場所に保管し、直日光から隔離してください。SDS(安全データシート)を参照してく...
掲載誌
Polymer Chemistry

Polymer Chemistry welcomes submissions in all areas of polymer science that have a strong focus on macromolecular chemistry. Manuscripts may cover a broad range of fields, yet no direct application focus is required.














