One-pot controllable synthesis of oligo(carbonate-ether) triol using a Zn-Co-DMC catalyst: the special role of trimesic acid as an initiation-transfer agent

文献情報

出版日 2014-06-30
DOI 10.1039/C4PY00578C
インパクトファクター 5.582
著者

Yusheng Qin, Xuesi Chen, Xianhong Wang, Fosong Wang


原文を見る

要旨

A one-pot synthesis of oligo(carbonate-ether) triol was realized by the copolymerization of CO2 and propylene oxide (PO) using a zinc-cobalt double metal cyanide (Zn-Co-DMC) catalyst in the presence of 1,3,5-benzenetricarboxylic (trimesic) acid (TMA). The catalytic activity ranged from 0.3 to 1.0 kg g−1 DMC under various copolymerization conditions. The structure of the oligo(carbonate-ether) triol was clearly confirmed, providing sound evidence for the special role played by the TMA, i.e., that it acted as an initiation-transfer agent. In the first stage the TMA initiated PO homo-polymerization to afford oligo-ether triol via a core-first approach in the presence of Zn-Co-DMC. After all of the TMA was consumed, the in situ formed oligo-ether triol acted as new chain transfer agent to participate in the copolymerization, forming carbonate-ether segments and therefore the oligo(carbonate-ether) triol. Since every molecule of TMA participated in initiation and propagation steps, the molecular weight of the triol depended on the amount of TMA used rather than the amount of Zn-Co-DMC. Consequently, the number average molecular weight (Mn) of the oligo(carbonate-ether) triol could be well controlled from 1400 to 3800 g mol−1 with a relatively narrow polydispersity index (PDI) (1.15–1.45), and its carbonate unit content (CU) could be adjusted between 20% and 54%.

関連文献

Coumarin meets fluorescein: a Förster resonance energy transfer enhanced optical ammonia gas sensor

Marko Dorrestijn, Agathe Camerlo, Špela Korent Urek, Aleksandra Lobnik, Catherine E. Housecroft, Edwin C. Constable, Lukas J. Scherer

2014-06-24 Paper

DOI: 10.1039/C4AN00061G

Front cover

Cover

DOI: 10.1039/C4AN90071E

In Situ metabolic analysis of single plant cells by capillary microsampling and electrospray ionization mass spectrometry with ion mobility separation

Linwen Zhang, Daniel P. Foreman, Paaqua A. Grant, Bindesh Shrestha, Sally A. Moody, Florent Villiers, June M. Kwak, Akos Vertes

2014-07-28 Paper

DOI: 10.1039/C4AN01018C

Plasmonic nanoparticle-film calipers for rapid and ultrasensitive dimensional and refractometric detection

Chen-Chieh Yu, Keng-Te Lin, Yi-Chuan Tseng, Sin-Yi Chou, Chang-Ching Shao, Hsuen-Li Chen, Wei-Fang Su

2014-07-23 Paper

DOI: 10.1039/C4AN00186A

High throughput volatile fatty acid skin metabolite profiling by thermal desorption secondary electrospray ionisation mass spectrometry

Helen J. Martin, James C. Reynolds, Svetlana Riazanskaia, C. L. Paul Thomas

2014-05-16 Paper

DOI: 10.1039/C4AN00134F

Affinity-based precipitation via a bivalent peptidic hapten for the purification of monoclonal antibodies

Michael W. Handlogten, Jared F. Stefanick, Peter E. Deak

2014-06-12 Paper

DOI: 10.1039/C4AN00780H

Inside back cover

Cover

DOI: 10.1039/C4AN90088J

Electrochemistry provides a point-of-care approach for the marker indicative of Pseudomonas aeruginosa infection of cystic fibrosis patients

Jonathan P. Metters, Dimitrios K. Kampouris, Craig E. Banks

2014-06-13 Paper

DOI: 10.1039/C4AN00675E

こちらもおすすめ

化合物よくある質問

3-(5-フェニル-2-ファイル)-プロパン酸の市場動向や研究トレンドはどうですか?

この化合物の市場動向は不明ですが、類似化合物の需要は化学繊維、医薬品、農薬分野で安定しています。研究トレンドとしては、該当化合物の生物学的活性の評価や、その他の...

3465-61-03-(5-Phenyl-2-furyl)...
化合物よくある質問

3- Chloro-1H-indazol-5-olはどのように保存すればよいですか?

3- チロロ-1H-吲唑-5-醇は遮光し、直射日光を避けて、温度は室温を推奨し、密閉容器に保存してください。

885519-34-63-Chloro-1H-indazol-...
化合物よくある質問

二茂鐵是安全的吗?

二茂鐵在使用时需要谨慎,因为它具有一定的刺激性。在操作时应佩戴防护眼镜和手套,保持通风良好的环境,并避免皮肤接触和吸入。

849924-76-11,2,3,4,5-Cyclopenta...
化合物よくある質問

L-(1-~13~C)メチオニンの市場動向や研究トレンドはどうですか?

L-(1-~13~C)メチオニンは、医薬品やバイオテクノロジー分野での研究が増加しており、その価格は安定しています。新興研究分野では、代謝解析や遺伝子機能解析で...

81202-04-2L-(1-~13~C)Methionin...
化合物よくある質問

1,3-フェニレンビスメチレンビスアクリレートは安全ですか?

1,3-フェニレンビスメチレンビスアクリレートは一般的に安全ですが、直接皮膚に触れる場合は保護用具を使用することを推奨します。高濃度の蒸気が吸入された場合は呼吸...

22757-16-01,3-Phenylenebis(met...
化合物よくある質問

丹参醇Aはどのように保存すればよいですか?

丹参醇Aは、直射日光を避けて室温で保存し、密栓容器に入れることをお勧めします。適切な保存条件は、安定性を保ち、安全性を確保する上で重要です。

189308-08-5Danshenol A
化合物よくある質問

4-メチル-2-(1,1,1-三フロロ-2-メチルプロパニル)ピリドインとは何ですか?

CAS番号1378865-93-0の4-メチル-2-(1,1,1-三フロロ-2-メチルプロパニル)ピリドインは、合成化学分野で用いられる有機化合物の一種です。こ...

1378865-93-04-Methyl-2-(1,1,1-tr...
化合物よくある質問

N-フェニルベンジル-2-クロロ酢氨を取り扱う際の実験室安全事項は何ですか?

N-フェニルベンジル-2-クロロ酢氨は毒性があり、皮膚や粘膜に刺激を与えます。取り扱う際には、保護眼鏡、手袋、ゴーグルを着用することを強く推奨します。ドラフトチ...

2653-14-7N-benzyl-2-chloro-N-...
化合物よくある質問

UCN-02を取り扱う際の実験室安全事項は何ですか?

UCN-02は毒性は低いですが、人体への直接的な接触は避けるべきです。PPE要件はグローブと顔面保護具を着用することです。ドラフトチャンバーを使用して漏洩を処理...

化合物よくある質問

N-[3-[2-(二甲基氨基)乙氧基]-4-甲氧基苯基]-2'-甲基-4'-(5-甲基-1,2,4-恶二唑-3-基)-[1,1'-联苯]-4-甲酰胺を取り扱う際の実験室安全事項は何ですか?

手袋と保護眼鏡を着用し、漏洩時には吸気防止装置を使用してください。室温、乾燥した場所に保管し、直日光から隔離してください。SDS(安全データシート)を参照してく...

170230-39-4N-{3-[2-(Dimethylami...

掲載誌

Polymer Chemistry

Polymer Chemistry
CiteScore: 8.6
自己引用率: 7.3%
年間論文数: 457

Polymer Chemistry welcomes submissions in all areas of polymer science that have a strong focus on macromolecular chemistry. Manuscripts may cover a broad range of fields, yet no direct application focus is required.

おすすめサプライヤー

免責事項
このページに表示される学術雑誌情報は、参考および研究目的のみを目的としています。当社は雑誌出版社とは提携しておらず、投稿の取り扱いも行っておりません。出版に関するお問い合わせは、各雑誌出版社に直接ご連絡ください。
表示されている情報に誤りがある場合は、support@chemtradehub.com までご連絡ください。迅速に確認し、対応いたします。