Dip-pen microarraying of molecular beacon probes on microgel thin-film substrates
文献情報
Xiaoguang Dai, Matthew Libera
The integration of microarray-based nucleic acid detection technologies and microfluidics is attractive, because the combination of small sample volumes, relatively short diffusion distances, and solid-phase detection enhances the development of multiplexed assays with improved sensitivity and minimal sample size. However, traditional microarray spotting methods typically create probe spot sizes of ∼50–100 μm diameter, comparable to the dimensions of many microfluidic channels. In addition, detection of hybridization events typically requires a post-hybridization labeling step. We address both issues by exploring the use of dip-pen nanolithography (DPN) to pattern linear oligonucleotides and self-reporting molecular beacon (MB) probes on streptavidin-functionalized poly(ethylene glycol) microgel thin-film substrates. In contrast to many systems involving DPN deposition, the fluorescence of the labeled probes enables their amount and spatial distribution to be characterized by optical microscopy. Their deposition rate decreases with increasing DPN dwell time, consistent with a Langmuir adsorption model, but the linear relationship between spot diameter and time1/2 indicates that spot size is diffusion controlled. We then use DPN to pattern MB probes for the mecA and spa genes in Staphylococcus aureus as a 2-column array with 1 μm spot sizes and 5 μm spot spacings, and we use this array to differentiate targets characteristic of methicillin-resistant S. aureus (MRSA) and methicillin-sensitive S. aureus. This duplexed self-reporting gel-tethered MB microarray not only shows high specificity but also a high signal-to-background ratio.
関連文献
Exciplex emission from the mixed dimer of naphthalene and 2-cyanonaphthalene in a supersonic jet
Aloke Das, K. K. Mahato, Chayan K. Nandi, Tapas Chakraborty, Shridhar R. Gadre, Nikhil A. Gokhale
DOI: 10.1039/B200124C
Probing boundary sites on a Pt/Al2O3 model catalyst by CO2 hydrogenation and in situATR-IR spectroscopy of catalytic solid–liquid interfaces
Davide Ferri, Thomas Bürgi, Alfons Baiker
DOI: 10.1039/B111498K
Oscillations in the primary charge separation in bacterial photosynthesis
DOI: 10.1039/B102700J
Nano-Raman imaging of Cu–TCNQ clusters in TCNQ thin films by scanning near-field optical microscopy
P. G. Gucciardi, S. Trusso, C. Vasi, S. Patanè, M. Allegrini
DOI: 10.1039/B110475F
Morphology and oxide phase control in the microemulsion mediated synthesis of barium stabilized aluminananoparticles
Ioan Balint, Zhixiong You, Ken-ichi Aika
DOI: 10.1039/B202056D
Polarization properties of low frequency inelastic scattering by acoustic phonons in gold nanoclusters
A. Morresi, M. Ombelli, P. Sassi
DOI: 10.1039/B110225G
An X-ray absorption near edge spectroscopy study of trace amount technetium implanted in apatite
C. Gaillard, C. Den Auwer, S. D. Conradson
DOI: 10.1039/B202618J
A spectroscopic study of the fluorination and defluorination reactions on single-walled carbon nanotubes
Pierre R. Marcoux, Joachim Schreiber, Patrick Batail, Serge Lefrant, Joël Renouard, Guy Jacob, David Albertini, Jean-Yves Mevellec
DOI: 10.1039/B109770A
The effect of water on the enantioselective hydrogenation of ethyl pyruvate and butane-2,3-dione using cinchona-modified Pt/Al2O3
Richard P. K. Wells, Neil R. McGuire, Xiaobao Li, Robert L. Jenkins, Paul J. Collier, Robin Whyman, Graham J. Hutchings
DOI: 10.1039/B200099G
こちらもおすすめ
3-(5-フェニル-2-ファイル)-プロパン酸の市場動向や研究トレンドはどうですか?
この化合物の市場動向は不明ですが、類似化合物の需要は化学繊維、医薬品、農薬分野で安定しています。研究トレンドとしては、該当化合物の生物学的活性の評価や、その他の...
3- Chloro-1H-indazol-5-olはどのように保存すればよいですか?
3- チロロ-1H-吲唑-5-醇は遮光し、直射日光を避けて、温度は室温を推奨し、密閉容器に保存してください。
L-(1-~13~C)メチオニンの市場動向や研究トレンドはどうですか?
L-(1-~13~C)メチオニンは、医薬品やバイオテクノロジー分野での研究が増加しており、その価格は安定しています。新興研究分野では、代謝解析や遺伝子機能解析で...
1,3-フェニレンビスメチレンビスアクリレートは安全ですか?
1,3-フェニレンビスメチレンビスアクリレートは一般的に安全ですが、直接皮膚に触れる場合は保護用具を使用することを推奨します。高濃度の蒸気が吸入された場合は呼吸...
丹参醇Aはどのように保存すればよいですか?
丹参醇Aは、直射日光を避けて室温で保存し、密栓容器に入れることをお勧めします。適切な保存条件は、安定性を保ち、安全性を確保する上で重要です。
4-メチル-2-(1,1,1-三フロロ-2-メチルプロパニル)ピリドインとは何ですか?
CAS番号1378865-93-0の4-メチル-2-(1,1,1-三フロロ-2-メチルプロパニル)ピリドインは、合成化学分野で用いられる有機化合物の一種です。こ...
N-フェニルベンジル-2-クロロ酢氨を取り扱う際の実験室安全事項は何ですか?
N-フェニルベンジル-2-クロロ酢氨は毒性があり、皮膚や粘膜に刺激を与えます。取り扱う際には、保護眼鏡、手袋、ゴーグルを着用することを強く推奨します。ドラフトチ...
UCN-02を取り扱う際の実験室安全事項は何ですか?
UCN-02は毒性は低いですが、人体への直接的な接触は避けるべきです。PPE要件はグローブと顔面保護具を着用することです。ドラフトチャンバーを使用して漏洩を処理...
N-[3-[2-(二甲基氨基)乙氧基]-4-甲氧基苯基]-2'-甲基-4'-(5-甲基-1,2,4-恶二唑-3-基)-[1,1'-联苯]-4-甲酰胺を取り扱う際の実験室安全事項は何ですか?
手袋と保護眼鏡を着用し、漏洩時には吸気防止装置を使用してください。室温、乾燥した場所に保管し、直日光から隔離してください。SDS(安全データシート)を参照してく...
掲載誌
Analyst

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.














