Low voltage electrically stimulated lab-on-a-chip device followed by red-green-blue analysis: a simple and efficient design for complicated matrices

文献情報

出版日 2014-08-15
DOI 10.1039/C4AN01124D
インパクトファクター 4.616
著者

Shahram Seidi, Maryam Rezazadeh, Yadollah Yamini, Niki Zamani, Sara Esmaili


原文を見る

要旨

In the present work, a simple and portable analysis device was designed for the first time for the determination of lead ions as the model analyte. The basis of the lead analysis is its extraction and pre-concentration in an acceptor droplet via the application of an electrical field. The acceptor droplet is a KI solution and therefore, the formation of a yellow precipitation of PbI2 was a sign of the presence of lead ion in the solution. Following this, digital picture of the final acceptor droplet was analyzed by investigating its Red-Green-Blue (RGB) components. The results show that the RGB intensities of the acceptor phase are proportionate to the lead concentration in the sample solution. Also, a 9.0 V battery was used to apply the electrical field, and other effective parameters, such as the type of organic liquid membrane, pH of the sample solution, and the extraction time, were considered to obtain the optimal conditions. The model analyte was determined by extracting it from a 100 μL sample solution across a thin layer of 1-octanol, immobilized in the pores of a polypropylene membrane sheet, and into the acceptor droplet via applying a 9.0 V electrical potential for 20 min. The device is capable of determining lead ions down to 20.0 ng mL−1, with admissible repeatability and reproducibility (the intra- and inter-assay precision ranged between 3.8–7.0% and 9.8–11.9%, respectively). Also, we calculated error% for the model analyte in the range of −8.5 to +4.5, which suggests that the chip offers acceptable accuracy for the analysis of lead ions. The linearity was studied in the range of 50.0–1500 ng mL−1, with a correlation coefficient of 0.9994. Finally, the designed device was used for the analysis of lead in real samples.

関連文献

Active sites in sol–gel prepared silica-alumina for photoinduced non-oxidative methane coupling

Hisao Yoshida, Norimitsu Matsushita, Yuko Kato, Tadashi Hattori

2002-04-22 Paper

DOI: 10.1039/B111101A

Polarization properties of low frequency inelastic scattering by acoustic phonons in gold nanoclusters

A. Morresi, M. Ombelli, P. Sassi

2002-02-21 Paper

DOI: 10.1039/B110225G

Fragmentations and reactions of three isotopically labelled dimethyl methylphosphonate ions produced by electrospray ionisation in an ion trap mass spectrometer

J. D. Barr, A. J. Bell, D. O. Konn, J. Murrell, C. M. Timperley, M. J. Waters, P. Watts

2002-05-03 Paper

DOI: 10.1039/B111192M

Aggregate formation in mixed monolayers at the air–water interface of metal-complex tetracationic water-soluble porphyrins attached to a phospholipid matrix

José M. Pedrosa, Marta Pérez, Inmaculada Prieto, María Teresa Martín-Romero, Dietmar Möbius, Luis Camacho

2002-04-29 Paper

DOI: 10.1039/B108360K

Surface features and catalytic activity of sulfated zirconia catalysts from hydrothermal precursors

C. Morterra, G. Cerrato, S. Ardizzone, C. L. Bianchi, M. Signoretto, F. Pinna

2002-05-30 Paper

DOI: 10.1039/B110444F

NO reduction with CO in the presence of O2 over Al2O3-supported and Cu-based catalysts

Takashi Yamamoto, Tsunehiro Tanaka, Ryoji Kuma, Sosuke Suzuki, Fumiaki Amano, Yutaka Shimooka, Yoshiumi Kohno, Takuzo Funabiki, Satohiro Yoshida

2002-04-29 Paper

DOI: 10.1039/B201120B

Surface reactivity of prereduced rare earth oxides with nitric oxide: New approach for NO decomposition

Masaaki Haneda, Yoshiaki Kintaichi, Hideaki Hamada

2002-05-17 Paper

DOI: 10.1039/B201340A

こちらもおすすめ

化合物よくある質問

3-(5-フェニル-2-ファイル)-プロパン酸の市場動向や研究トレンドはどうですか?

この化合物の市場動向は不明ですが、類似化合物の需要は化学繊維、医薬品、農薬分野で安定しています。研究トレンドとしては、該当化合物の生物学的活性の評価や、その他の...

3465-61-03-(5-Phenyl-2-furyl)...
化合物よくある質問

3- Chloro-1H-indazol-5-olはどのように保存すればよいですか?

3- チロロ-1H-吲唑-5-醇は遮光し、直射日光を避けて、温度は室温を推奨し、密閉容器に保存してください。

885519-34-63-Chloro-1H-indazol-...
化合物よくある質問

二茂鐵是安全的吗?

二茂鐵在使用时需要谨慎,因为它具有一定的刺激性。在操作时应佩戴防护眼镜和手套,保持通风良好的环境,并避免皮肤接触和吸入。

849924-76-11,2,3,4,5-Cyclopenta...
化合物よくある質問

L-(1-~13~C)メチオニンの市場動向や研究トレンドはどうですか?

L-(1-~13~C)メチオニンは、医薬品やバイオテクノロジー分野での研究が増加しており、その価格は安定しています。新興研究分野では、代謝解析や遺伝子機能解析で...

81202-04-2L-(1-~13~C)Methionin...
化合物よくある質問

1,3-フェニレンビスメチレンビスアクリレートは安全ですか?

1,3-フェニレンビスメチレンビスアクリレートは一般的に安全ですが、直接皮膚に触れる場合は保護用具を使用することを推奨します。高濃度の蒸気が吸入された場合は呼吸...

22757-16-01,3-Phenylenebis(met...
化合物よくある質問

丹参醇Aはどのように保存すればよいですか?

丹参醇Aは、直射日光を避けて室温で保存し、密栓容器に入れることをお勧めします。適切な保存条件は、安定性を保ち、安全性を確保する上で重要です。

189308-08-5Danshenol A
化合物よくある質問

4-メチル-2-(1,1,1-三フロロ-2-メチルプロパニル)ピリドインとは何ですか?

CAS番号1378865-93-0の4-メチル-2-(1,1,1-三フロロ-2-メチルプロパニル)ピリドインは、合成化学分野で用いられる有機化合物の一種です。こ...

1378865-93-04-Methyl-2-(1,1,1-tr...
化合物よくある質問

N-フェニルベンジル-2-クロロ酢氨を取り扱う際の実験室安全事項は何ですか?

N-フェニルベンジル-2-クロロ酢氨は毒性があり、皮膚や粘膜に刺激を与えます。取り扱う際には、保護眼鏡、手袋、ゴーグルを着用することを強く推奨します。ドラフトチ...

2653-14-7N-benzyl-2-chloro-N-...
化合物よくある質問

UCN-02を取り扱う際の実験室安全事項は何ですか?

UCN-02は毒性は低いですが、人体への直接的な接触は避けるべきです。PPE要件はグローブと顔面保護具を着用することです。ドラフトチャンバーを使用して漏洩を処理...

化合物よくある質問

N-[3-[2-(二甲基氨基)乙氧基]-4-甲氧基苯基]-2'-甲基-4'-(5-甲基-1,2,4-恶二唑-3-基)-[1,1'-联苯]-4-甲酰胺を取り扱う際の実験室安全事項は何ですか?

手袋と保護眼鏡を着用し、漏洩時には吸気防止装置を使用してください。室温、乾燥した場所に保管し、直日光から隔離してください。SDS(安全データシート)を参照してく...

170230-39-4N-{3-[2-(Dimethylami...

掲載誌

Analyst

Analyst
CiteScore: 7.8
自己引用率: 5.6%
年間論文数: 653

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.

おすすめサプライヤー

免責事項
このページに表示される学術雑誌情報は、参考および研究目的のみを目的としています。当社は雑誌出版社とは提携しておらず、投稿の取り扱いも行っておりません。出版に関するお問い合わせは、各雑誌出版社に直接ご連絡ください。
表示されている情報に誤りがある場合は、support@chemtradehub.com までご連絡ください。迅速に確認し、対応いたします。