Novel DFO-functionalized mesoporous silica for iron sensing. Part 2. Experimental detection of free iron concentration (pFe) in urine samples

文献情報

出版日 2014-03-13
DOI 10.1039/C3AN01488F
インパクトファクター 4.616
著者

Giancarla Alberti, Giovanni Emma, Roberta Colleoni, Maria Pesavento, Valeria Marina Nurchi, Raffaela Biesuz


原文を見る

要旨

Successful in vivo chelation treatment of iron(III) overload pathologies requires that a significant fraction of the administered drug actually chelates the toxic metal. Increased mobilization of the iron(III) in experiments on animals or humans, most often evaluated from urinary output, is usually used as an assessment tool for chelation therapy. Alternatively, the efficiency of a drug is estimated by calculating the complexing ability of a chelating agent towards Fe(III). The latter is calculated by the pFe value, defined as the negative logarithm of the concentration of the free metal ion in a solution containing 10 μM total ligand and 1 μM total metal at a physiological pH of 7.4. In theory, pFe has to be calculated taking into account all the complexation equilibria involving the metal and the possible ligands. Nevertheless, complexation reactions in complex systems such as serum and urine may hardly be accurately modelled by computer software. The experimental determination of the bioavailable fraction of iron(III) in biological fluids would therefore be of the utmost relevance in the clinical practice. The efficiency of the therapy could be more easily estimated as well as the course of overload pathologies. In this context, the aim of the present work was the development of a sensor to assess the free iron directly in biological fluids (urine) of patients under treatment with chelating agents. In the proposed device (DFO-MS), the strong iron chelator deferoxamine (DFO) is immobilized on the MCM-41 mesoporous silica. The characterization of the iron(III) sorption on DFO-MS was undertaken, firstly in 0.1 M KNO3, then directly in urine samples, in order to identify the sorption mechanism. The stoichiometry of the reaction in the solid phase was found to be: with an exchange constant (average value) of log βex = 40(1). The application of DFO-MS to assess pFe in SPU (Simulating Pathology Urine) samples was also considered. The results obtained were very promising for a future validation and subsequent application of the sensor in samples of patients undergoing chelation therapy.

関連文献

A Mössbauer study of In–Fe2O3/HZSM-5 catalysts for the selective catalytic reduction of NO by methane

Xiaodong Wang, Xuqun Zhao, Jianyi Shen, Xiaoying Sun, Tao Zhang, Liwu Lin

2002-05-15 Paper

DOI: 10.1039/B110515A

High pressure, high temperature shock tube studies of ethanepyrolysis and oxidation

Robert S. Tranter, Raghu Sivaramakrishnan, Kenneth Brezinsky, Mark D. Allendorf

2002-03-12 Paper

DOI: 10.1039/B110702J

A model of the motion of a long DNA chain in a pulsed electric field

V. V. Chasovskikh, L. L. Frumin, S. E. Peltek, G. V. Zilberstein

2002-05-08 Paper

DOI: 10.1039/B110042D

A spectroscopic study of the fluorination and defluorination reactions on single-walled carbon nanotubes

Pierre R. Marcoux, Joachim Schreiber, Patrick Batail, Serge Lefrant, Joël Renouard, Guy Jacob, David Albertini, Jean-Yves Mevellec

2002-05-02 Paper

DOI: 10.1039/B109770A

Two ways of looking at Prigogine and Defay's equation

Luís P. N. Rebelo, Vesna Najdanovic-Visak, Zoran P. Visak, M. Nunes da Ponte, Jacobo Troncoso, Claudio A. Cerdeiriña, Luis Romaní

2002-04-25 Paper

DOI: 10.1039/B200292B

Solvent distribution in non-ionic surfactant monolayers

R. K. Thomas

2002-05-10 Paper

DOI: 10.1039/B108698G

Surface features and catalytic activity of sulfated zirconia catalysts from hydrothermal precursors

C. Morterra, G. Cerrato, S. Ardizzone, C. L. Bianchi, M. Signoretto, F. Pinna

2002-05-30 Paper

DOI: 10.1039/B110444F

こちらもおすすめ

化合物よくある質問

3-(5-フェニル-2-ファイル)-プロパン酸の市場動向や研究トレンドはどうですか?

この化合物の市場動向は不明ですが、類似化合物の需要は化学繊維、医薬品、農薬分野で安定しています。研究トレンドとしては、該当化合物の生物学的活性の評価や、その他の...

3465-61-03-(5-Phenyl-2-furyl)...
化合物よくある質問

3- Chloro-1H-indazol-5-olはどのように保存すればよいですか?

3- チロロ-1H-吲唑-5-醇は遮光し、直射日光を避けて、温度は室温を推奨し、密閉容器に保存してください。

885519-34-63-Chloro-1H-indazol-...
化合物よくある質問

二茂鐵是安全的吗?

二茂鐵在使用时需要谨慎,因为它具有一定的刺激性。在操作时应佩戴防护眼镜和手套,保持通风良好的环境,并避免皮肤接触和吸入。

849924-76-11,2,3,4,5-Cyclopenta...
化合物よくある質問

L-(1-~13~C)メチオニンの市場動向や研究トレンドはどうですか?

L-(1-~13~C)メチオニンは、医薬品やバイオテクノロジー分野での研究が増加しており、その価格は安定しています。新興研究分野では、代謝解析や遺伝子機能解析で...

81202-04-2L-(1-~13~C)Methionin...
化合物よくある質問

1,3-フェニレンビスメチレンビスアクリレートは安全ですか?

1,3-フェニレンビスメチレンビスアクリレートは一般的に安全ですが、直接皮膚に触れる場合は保護用具を使用することを推奨します。高濃度の蒸気が吸入された場合は呼吸...

22757-16-01,3-Phenylenebis(met...
化合物よくある質問

丹参醇Aはどのように保存すればよいですか?

丹参醇Aは、直射日光を避けて室温で保存し、密栓容器に入れることをお勧めします。適切な保存条件は、安定性を保ち、安全性を確保する上で重要です。

189308-08-5Danshenol A
化合物よくある質問

4-メチル-2-(1,1,1-三フロロ-2-メチルプロパニル)ピリドインとは何ですか?

CAS番号1378865-93-0の4-メチル-2-(1,1,1-三フロロ-2-メチルプロパニル)ピリドインは、合成化学分野で用いられる有機化合物の一種です。こ...

1378865-93-04-Methyl-2-(1,1,1-tr...
化合物よくある質問

N-フェニルベンジル-2-クロロ酢氨を取り扱う際の実験室安全事項は何ですか?

N-フェニルベンジル-2-クロロ酢氨は毒性があり、皮膚や粘膜に刺激を与えます。取り扱う際には、保護眼鏡、手袋、ゴーグルを着用することを強く推奨します。ドラフトチ...

2653-14-7N-benzyl-2-chloro-N-...
化合物よくある質問

UCN-02を取り扱う際の実験室安全事項は何ですか?

UCN-02は毒性は低いですが、人体への直接的な接触は避けるべきです。PPE要件はグローブと顔面保護具を着用することです。ドラフトチャンバーを使用して漏洩を処理...

化合物よくある質問

N-[3-[2-(二甲基氨基)乙氧基]-4-甲氧基苯基]-2'-甲基-4'-(5-甲基-1,2,4-恶二唑-3-基)-[1,1'-联苯]-4-甲酰胺を取り扱う際の実験室安全事項は何ですか?

手袋と保護眼鏡を着用し、漏洩時には吸気防止装置を使用してください。室温、乾燥した場所に保管し、直日光から隔離してください。SDS(安全データシート)を参照してく...

170230-39-4N-{3-[2-(Dimethylami...

掲載誌

Analyst

Analyst
CiteScore: 7.8
自己引用率: 5.6%
年間論文数: 653

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.

おすすめ化合物

おすすめサプライヤー

免責事項
このページに表示される学術雑誌情報は、参考および研究目的のみを目的としています。当社は雑誌出版社とは提携しておらず、投稿の取り扱いも行っておりません。出版に関するお問い合わせは、各雑誌出版社に直接ご連絡ください。
表示されている情報に誤りがある場合は、support@chemtradehub.com までご連絡ください。迅速に確認し、対応いたします。