Microfluidic technologies as platforms for performing quantitative cellular analyses in an in vitro environment
文献情報
R. Scott Martin, Paul D. Root, Dana M. Spence
Quite often, important cellular events occur in environments that are either not amenable to implanted sensors or other types of molecular probes. In such cases, a viable alternative to taking the sensor or probe to the biological sample of interest is to bring the sample of interest out of its natural environment to one that is more conducive to the measurement scheme. The disadvantage of the latter approach is that the sample may not behave in the same manner in vitro as it does in vivo, or that the agonists and other stimuli to which the sample is subjected to in vivo are no longer present. In this Tutorial Review, the authors attempt to provide some guidance, based on their own experiences and those of other scientists, to performing cellular measurements in a quantitative manner under in vitro conditions. Due to the expansive literature on analyses involving cells, the authors have limited this Tutorial Review to those methods involving microfluidic technologies, both in microbore tubing and in microfabricated channels. Initial reports of analyses involving cells in microbore tubing were first reported nearly two decades ago, while those in microfabricated fluidic devices appeared over a decade ago. However, more recently, the complexity of cell analyses using fabricated microfluidic devices (as opposed to microbore tubing) has increased due in part to the improvements in fabrication technologies, fluid handling and delivery capabilities, advances in coatings of the channels within the microfluidic device, and integrated detection schemes. Examples of cellular analyses in microbore tubing and in fabricated microfluidic devices will be given, as well as associated advantages and challenges. Finally, the authors' thoughts on cellular analyses are presented here using the classical steps in an analysis as a guide.
おすすめジャーナル

Critical Reviews in Solid State and Materials Sciences

Biocatalysis and Biotransformation

Acta Metallurgica Sinica-English Letters

Bioorganic & Medicinal Chemistry Letters

Topics in Catalysis

Journal of the Indian Institute of Science

Atomization and Sprays

Colloid Journal

Electroanalysis

Journal of Chemical Sciences
関連文献
Ethoxy and silsesquioxane derivatives of antimony as dopant precursors: unravelling the structure and thermal stability of surface species on SiO2
P. Florian, C. Thieuleux
DOI: 10.1039/C6CP08583K
Evidence for photosensitised hydrogen production from water in the absence of precious metals, redox-mediators and co-catalysts
S. Salzl, M. Ertl, G. Knör
DOI: 10.1039/C6CP07725K
How persistent microbubbles shield nanoparticle productivity in laser synthesis of colloids – quantification of their volume, dwell dynamics, and gas composition
Niko Bärsch, René Streubel, Emine Gökce, Stephan Barcikowski, Bilal Gökce
DOI: 10.1039/C6CP07011F
Proton transfer dynamics dictate quinone speciation at lipid-modified electrodes
Edmund C. M. Tse, Christopher J. Barile, Ying Li, Steven C. Zimmerman, Ali Hosseini
DOI: 10.1039/C6CP07586J
Development of hybrid photocatalysts constructed with a metal complex and graphitic carbon nitride for visible-light-driven CO2 reduction
Ryo Kuriki, Kazuhiko Maeda
DOI: 10.1039/C6CP07973C
Wet chemical etching induced stress relaxed nanostructures on polar & non-polar epitaxial GaN films
Abhiram Gundimeda, Bhasker Gahtori, Nita Dilawar, Ved Varun Aggarwal, Manju Singh, Rajib Rakshit
DOI: 10.1039/C7CP00380C
In situ spectroscopic studies on vapor phase catalytic decomposition of dimethyl oxalate
Shweta Hegde, Kalsang Tharpa, Satyanarayana Reddy Akuri, Rakesh K., Ajay Kumar, Raj Deshpande, Sreejit A. Nair
DOI: 10.1039/C6CP07769B
Thermodynamic stability of stoichiometric LaFeO3 and BiFeO3: a hybrid DFT study
Eugene Heifets, Joachim Maier
DOI: 10.1039/C6CP07986E
Interfacial defects induced electronic property transformation at perovskite SrVO3/SrTiO3 and LaCrO3/SrTiO3 heterointerfaces
Junjie Li, Deqiang Yin, Qiang Li, Rong Sun, Sumei Huang, Fanzhi Meng
DOI: 10.1039/C6CP07691B
Successive lithiation of acetylene, ethylene and benzene: a comprehensive computational study of large static second hyperpolarizability
Avijit Mondal, Kaushik Hatua, Ria Sinha Roy, Prasanta K. Nandi
DOI: 10.1039/C6CP07845A
こちらもおすすめ
S-(甲硅烷基丙基)異硫酰氯を取り扱う際の実験室安全事項は何ですか?
取り扱う際にはPPE(防護具)が必要です。特に手袋と面マスクは必須です。ドラフトチャンバーを使用して漏洩処理を行い、温度は常温、湿度は乾燥状態、容器はガラス容器...
8-硝基-咪唑并[1,2-a]吡啶とは何ですか?
8-硝基-咪唑并[1,2-a]吡啶は、CAS番号52310-46-0の化合物で、8-位に硝基を有する咪唑並みの结构をもつ吡啶の化合物です。この化合物は、酸化還元...
4-ブロモ-5-メトキシピリジン-2-甲醇の代替品はありますか?
4-ブロモ-5-メトキシピリジン-2-甲醇の代替品には、類似構造を持つ化合物や機能性に等しい代替試薬があります。例えば、4-クロロ-5-メトキシピリジン-2-甲...
全氟-1,2-二甲基環己烷を含む廃棄物はどのように処理すべきですか?
全氟-1,2-二甲基環己烷(CAS番号:306-98-9)の廃棄物は、特別な処理が必要です。まず、廃棄物を密閉容器に収集し、適切な防漏容器に保管します。次に、専...
3-(溴甲基)苯乙酸の主な用途は何ですか?
3-(溴甲基)苯乙酸は主に研究用化学薬品として利用され、有機合成や医薬品の開発に用いられます。また、特定の化合物の合成中間体としても使用されることがあります。
5-イドキド-4-メチオキシ-6-メチルピリミジニン-2-アミンはどのように保存すればよいですか?
5-イドキド-4-メチオキシ-6-メチルピリミジニン-2-アミンは冷暗所で密栓の容器に保存し、直射日光を避けて保管することをお勧めします。温度は常温とし、湿気を...
1-(2-溴-6-甲氧基苯基)乙酮を取り扱う際の実験室安全事項は何ですか?
実験室では、1-(2- Bromo-6-methoxyphenyl)ethanoneを取り扱う際には、ゴーグルや面具、手袋などのPPEを使用することが推奨されま...
5-(4,4,5,5-テトラメチル-1,3,2-ダイオキサボラロール-2-イル)-1,3-ジヒドロ-2-ベンゾフランは安全ですか?
5-(4,4,5,5-テトラメチル-1,3,2-ダイオキサボラロール-2-イル)-1,3-ジヒドロ-2-ベンゾフランは一般に安全ですが、取扱いには注意が必要です...
4-溴萘-1-甲酸の代替品はありますか?
4-溴萘-1-甲酸は比較的稀な化合物ですが、類似物としては、4-クロロ-1-ナフホリック酸やその他のブロモ置換ナフホリック酸が挙げられます。ただし、これらの代替...
ε-白藜芦醇脱氢二聚体の代替品はありますか?
ε-白藜芦醇脱氢二聚体の代替品としては、ε-白藜芦醇、ポリフェノール類、フラボノイド類が挙げられます。これらは類似の化学構造と生物学的活性を持っています。ただし...
掲載誌
Analyst

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.


![Sodium 3-[(E)-(4-anilinophenyl)diazenyl]benzenesulfonate structure Sodium 3-[(E)-(4-anilinophenyl)diazenyl]benzenesulfonate structure](https://static.chemtradehub.com/structs/587/587-98-4-035f.webp)

