Raman spectroscopy as a process analytical technology tool for the understanding and the quantitative in-line monitoring of the homogenization process of a pharmaceutical suspension

文献情報

出版日 2006-08-25
DOI 10.1039/B605299A
インパクトファクター 4.616
著者

T. R. M. De Beer, W. R. G. Baeyens, J. Ouyang, C. Vervaet, J. P. Remon


原文を見る

要旨

The aim of this study was to propose a Process Analytical Technology (PAT) strategy for the quantitative in-line monitoring of an aqueous pharmaceutical suspension using Raman spectroscopy. A screening design was used to study the significance of process variables (mixing speed and height of the stirrer in the reactor) and of formulation variables (concentration of the active pharmaceutical ingredient (API) ibuprofen and the viscosity enhancer (xanthan gum)) on the time required to homogenize an aqueous pharmaceutical model suspension as response variable. Ibuprofen concentration (10% and 15% (w/v)) and the height of stirrer (position 1 and 2) were discrete variables, whereas the viscosity enhancer (concentration range: 1–2 g Lāˆ’1) and the mixing speed (700–1000 rpm) were continuous variables. Next, a multilevel full factorial design was applied to study the effect of the remaining significant variables upon the homogenization process and to establish the optimum conditions for the process. Interactions between these variables were investigated as well. During each design experiment, the conformity index (CI) method was used to monitor homogeneity of the suspension mixing system in real-time using Raman spectroscopy in combination with a fibre optical immersion probe. Finally, a principal component regression (PCR) model was developed and evaluated to perform quantitative real-time and in-line measurements of the API during the mixing process. The experimental design results showed that the suspension homogenization process is an irregular process, for which it is impossible to model the studied variables upon the measured response variable. However, applying the PCR model it is possible to predict in-line and real-time the concentration of the API in a suspension during a mixing process. In this study, it is shown that Raman spectroscopy is a suitable PAT tool for the control of the homogenization process of an aqueous suspension. Raman spectroscopy not only allowed real-time monitoring of the homogeneity of the suspension, but also helped (in combination with experimental design) to understand the process. Further, the technique allowed real-time and in-line quantification of the API during the mixing process.

関連文献

Chemistry in supercritical fluids for the synthesis of metal nanomaterials

Yu Xu, Valentina Musumeci, Cyril Aymonier

2019-09-02 Review Article

DOI: 10.1039/C9RE00290A

Polymer–trimannoside conjugates via a combination of RAFT and thiol–ene chemistry

Debashish Roy, Bilal Ghosn, Eun-Ho Song, Daniel M. Ratner, Patrick S. Stayton

2012-11-14 Paper

DOI: 10.1039/C2PY20820B

Ionic liquid-functionalized LDH as catalytic-initiating nanoparticles for microwave-activated ring opening polymerization of ε-caprolactone

Sonia Bujok, Magdalena Konefał, Sabina Abbrent, Ewa Pavlova, Jan Svoboda, Olga Trhlíková, Zuzana Walterová, Hynek Beneš

2020-01-10 Paper

DOI: 10.1039/C9RE00399A

Contents list

Front/Back Matter

DOI: 10.1039/D0RE90028A

Neutral, anionic, cationic, and zwitterionic diblock copolymers featuring poly(2-methoxyethyl acrylate) “hydrophobic” segments

Irakli Javakhishvili, Katja Jankova, Søren Hvilsted

2012-09-26 Paper

DOI: 10.1039/C2PY20694C

Zero-valent metal catalyzed radical-induced adjustable removal/modification of thiocarbonylthio end groups of RAFT polymer at ambient temperature

Xiaofei Zhang, Wenxiang Wang, Kai Guo, Zhengbiao Zhang, Xiulin Zhu

2012-09-25 Paper

DOI: 10.1039/C2PY20667F

Mono- and di-cyclocarbonate telechelic polyolefins synthesized from ROMP using glycerol carbonate derivatives as chain-transfer agents

Liana Annunziata, Stéphane Fouquay, Guillaume Michaud, Frédéric Simon, Sophie M. Guillaume, Jean-François Carpentier

2013-01-08 Communication

DOI: 10.1039/C2PY21141F

Front cover

Cover

DOI: 10.1039/C9RE90067E

Modeling of RAFT polymerization of MMA in supercritical carbon dioxide using the PC-SAFT equation of state

Porfirio López-Domínguez, Jesús Eduardo Rivera-Peláez, Gabriel Jaramillo-Soto, José Fernando Barragán-Aroche

2020-01-24 Paper

DOI: 10.1039/C9RE00461K

Second-order isothermal reaction in a semi-batch reactor: modeling, exact analytical solution, and experimental verification

Mana Kord, Ali Nematollahzadeh, Behruz Mirzayi

2019-08-01 Paper

DOI: 10.1039/C9RE00174C

こちらもおすすめ

化合物よくある質問

1-{3-[5-(エチルカルボンイル)-2,4-ジメチル-1H-ピロロール-3-基]プロパニル}ピペリジン-4-カルボン酸について、適用される法規ガイドラインは何ですか?

この化合物はCAS番号1142209-81-1であり、GHS分類では corrosive (腐食性物質) と classified (分類物質) として指定され...

1142209-81-11-{3-[5-(Ethoxycarbo...
化合物よくある質問

2,2-二氟-1,3-ベンゾジオキサン-5-カルボキシlic酸とは何ですか?

2,2-二氟-1,3-ベンゾジオキサン-5-カルボキシlic酸は、CAS番号656-46-2の化合物で、化学式はC8H4F2O4です。この化合物は白色の結晶性粉...

656-46-22,2-Difluoro-1,3-ben...
化合物よくある質問

8-氯-4-色原酮の代替品はありますか?

8-氯-4-色原酮(CAS番号: 49701-11-3)の代替品には、他の色原酮類似物や、構造が似ている化合物があります。例えば、8-メチル-4-色原酮や、他の...

49701-11-38-Chloro-2,3-dihydro...
化合物よくある質問

エチル6,6-ジメチル-4,5,6,7-テトラヒドロ-1H-インドアゼー-3-カルボキシレートとは何ですか?

エチル6,6-ジメチル-4,5,6,7-テトラヒドロ-1H-インドアゼー-3-カルボキシレートは、CAS番号1233243-56-5を有する化合物です。これは有...

1233243-56-5Ethyl 6,6-dimethyl-4...
化合物よくある質問

4-叔丁基-6-氯-嘧啶に適用される法規ガイドラインは何ですか?

4-叔丁基-6-氯-嘧啶はCAS番号3435-24-3で、GHS分類では毒性物質とみなし、GHSの危険性分類が適用されます。REACH規則では登録が必要で、Eu...

3435-24-34-Tert-butyl-6-chlor...
化合物よくある質問

維库溴铵杂质Bはどのように合成されますか?

維库溴铵杂质Bは、アンドロステンデンから始まり、一連の合成反応、包括的な選択性と高い収率で合成されます。具体的には、ブロミド化、酸化、ジマーゼ反応、アミド化など...

50587-95-6(2beta,3alpha,5alpha...
化合物よくある質問

2-(4-氟苄基)-吡咯烷の物理化学的性質は何ですか?

CAS番号350017-04-8の2-(4-氟苄基)-吡咯烷は、結晶性の白色粉末です。分子量は199.17 g/molで、水に溶けにくいです。化学反応では比較的...

350017-04-82-(4-Fluorobenzyl)py...
化合物よくある質問

3-喹啉甲醛(2-チロール-8-エチル)は安全ですか?

3-喹啉甲醛(2-チロール-8-エチル)は一定の毒性を持つため、取扱には注意が必要です。使用する際は適切な防護具を着用し、密閉容器で保管・搬送し、直接的な接触を...

335196-05-92-Chloro-8-ethyl-3-q...
化合物よくある質問

エチル3-(ヒドロキシメチル)-1H-ピロール-2-カルボキシレートはどのように保存すればよいですか?

エチル3-(ヒドロキシメチル)-1H-ピロール-2-カルボキシレートは、室温(25℃)以下で保存し、直射日光を避け、乾燥した環境で保管することが推奨されます。ま...

75448-69-0Ethyl 3-(hydroxymeth...
化合物よくある質問

哌拉西林杂质Dは安全ですか?

哌拉西林杂质Dは安全性が確認されていません。使用または取り扱いには注意が必要で、適切な個人防護具を使用し、直接的な接触を避けることが推奨されます。

119410-05-88-Chloro-11-(4-piper...

掲載誌

Analyst

Analyst
CiteScore: 7.8
自己引用率: 5.6%
年間論文数: 653

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.

おすすめ化合物

おすすめサプライヤー

免責事項
このページに表示される学術雑誌情報は、参考および研究目的のみを目的としています。当社は雑誌出版社とは提携しておらず、投稿の取り扱いも行っておりません。出版に関するお問い合わせは、各雑誌出版社に直接ご連絡ください。
表示されている情報に誤りがある場合は、support@chemtradehub.com までご連絡ください。迅速に確認し、対応いたします。