Determination of benzo[a]pyrene tetrols by column-switching capillary liquid chromatography with fluorescence and micro-electrospray ionization mass spectrometric detection
文献情報
Elsa Lundanes, Tyge Greibrokk
The present work displays capillary liquid chromatographic column switching methodology tailored for determination of benzo[a]pyrene tetrol isomers in biological matrices using on-line fluorescence and μ-electrospray ionization mass spectrometric detection. A well-established off-line crude solid phase extraction procedure was used in order to make the method compatible with several biological matrices. The solid phase extraction eluates were evaporated to dryness, redissolved in 1.0 ml methanol : water (10 : 90, v/v), loaded onto a 0.32 mm I.D. × 40 mm 5 µm Kromasil C18 pre-column for analyte enrichment and back-flushed elution onto a 0.30 mm I.D. × 150 mm 3.5 µm Kromasil C18 analytical column. The samples were loaded with a flow rate of 50 µl min−1 and the tetrols were separated at a flow rate of 4 µl min−1 with an acetonitrile : 10 mM ammonium acetate gradient from 10 to 90%. A sample loading flow rate up to 50 µl min−1 was allowed. The fluorescence excitation and emission were set to 342 and 385 nm, respectively, while mass spectrometric detection of the benzo[a]pyrene tetrols was obtained by monitoring their [M − H]− molecular ions at m/z 319. The method was validated over the concentration range 0.1–50 ng ml−1 benzo[a]pyrene tetrols in a cell culture medium with 100 µl injection volume, fluorescence detection and the first eluting tetrol isomer as model compound, resulting in a correlation coefficient of 0.993. The within-assay (n = 6) and between-assay (n = 6) precisions were determined to 2.6–8.6% and 3.8–9.6%, respectively, and the recoveries were determined to 97.9–102.4% within the investigated concentration range. The mass limit of detection (by fluorescence) was 3 pg for all the tetrol isomers, corresponding to a concentration limit of detection of 30 pg ml−1 cell culture medium. The corresponding mass spectrometric mass limits of detection were 4–10 pg, corresponding to concentration limits of detection of 40–100 pg ml−1 cell culture medium.
関連文献
Structural characterization and electronic properties of Ni/rubrene bilayers with alternative stacking sequences
Ranganadha Gopalarao Tanguturi, Jian-Chen Tsai, You-Siang Li, Jyh-Shen Tsay
DOI: 10.1039/D3CP00297G
Effects of layer-by-layer coating on activated carbon electrodes for capacitive deionization
Sergio Orozco-Barrera, Guillermo R. Iglesias, Ángel V. Delgado, Sergio García-Larios, Silvia Ahualli
DOI: 10.1039/D2CP05682H
InN/XS2 (X = Zr, Hf) vdW heterojunctions: promising Z-scheme systems with high hydrogen evolution activity for photocatalytic water splitting
DOI: 10.1039/D2CP05280F
Understanding the piezocatalytic properties of the BaTiO3(001) surface via density functional theory
DOI: 10.1039/D2CP05631C
Fungi-enabled pore channel regulation and defect engineering of a novel micro-reactor for treating complex effluents
Xiaoying Jiang, Yan Zhang, Feiyang Zhang, Jiashuo Tian, Liuping Zhang, Xinrui Zhao, Fengling Cui
DOI: 10.1039/D2CP05608A
Thermodynamic and optical properties of HCOOH(H2O)n and HCOOH(NH3)(H2O)(n−1) clusters at various temperatures and pressures: a computational study
Arnab Patla, Ranga Subramanian
DOI: 10.1039/D2CP03908G
Robust electronic properties of monolayer BeO against molecule adsorption
DOI: 10.1039/D2CP05980K
Future of computational molecular spectroscopy—from supporting interpretation to leading the innovation
DOI: 10.1039/D3CP00192J
A study on theoretical models for investigating time-resolved photoluminescence in halide perovskites
Jing Chen, Jing Lv, Xiaolin Liu, Jia Lin
DOI: 10.1039/D2CP05723A
Protonation of serine: conformers, proton affinities and gas-phase basicities at the “gold standard” and beyond
András B. Nacsa, Máté Kígyósi, Gábor Czakó
DOI: 10.1039/D3CP00612C
こちらもおすすめ
S-(甲硅烷基丙基)異硫酰氯を取り扱う際の実験室安全事項は何ですか?
取り扱う際にはPPE(防護具)が必要です。特に手袋と面マスクは必須です。ドラフトチャンバーを使用して漏洩処理を行い、温度は常温、湿度は乾燥状態、容器はガラス容器...
8-硝基-咪唑并[1,2-a]吡啶とは何ですか?
8-硝基-咪唑并[1,2-a]吡啶は、CAS番号52310-46-0の化合物で、8-位に硝基を有する咪唑並みの结构をもつ吡啶の化合物です。この化合物は、酸化還元...
4-ブロモ-5-メトキシピリジン-2-甲醇の代替品はありますか?
4-ブロモ-5-メトキシピリジン-2-甲醇の代替品には、類似構造を持つ化合物や機能性に等しい代替試薬があります。例えば、4-クロロ-5-メトキシピリジン-2-甲...
全氟-1,2-二甲基環己烷を含む廃棄物はどのように処理すべきですか?
全氟-1,2-二甲基環己烷(CAS番号:306-98-9)の廃棄物は、特別な処理が必要です。まず、廃棄物を密閉容器に収集し、適切な防漏容器に保管します。次に、専...
3-(溴甲基)苯乙酸の主な用途は何ですか?
3-(溴甲基)苯乙酸は主に研究用化学薬品として利用され、有機合成や医薬品の開発に用いられます。また、特定の化合物の合成中間体としても使用されることがあります。
5-イドキド-4-メチオキシ-6-メチルピリミジニン-2-アミンはどのように保存すればよいですか?
5-イドキド-4-メチオキシ-6-メチルピリミジニン-2-アミンは冷暗所で密栓の容器に保存し、直射日光を避けて保管することをお勧めします。温度は常温とし、湿気を...
1-(2-溴-6-甲氧基苯基)乙酮を取り扱う際の実験室安全事項は何ですか?
実験室では、1-(2- Bromo-6-methoxyphenyl)ethanoneを取り扱う際には、ゴーグルや面具、手袋などのPPEを使用することが推奨されま...
5-(4,4,5,5-テトラメチル-1,3,2-ダイオキサボラロール-2-イル)-1,3-ジヒドロ-2-ベンゾフランは安全ですか?
5-(4,4,5,5-テトラメチル-1,3,2-ダイオキサボラロール-2-イル)-1,3-ジヒドロ-2-ベンゾフランは一般に安全ですが、取扱いには注意が必要です...
4-溴萘-1-甲酸の代替品はありますか?
4-溴萘-1-甲酸は比較的稀な化合物ですが、類似物としては、4-クロロ-1-ナフホリック酸やその他のブロモ置換ナフホリック酸が挙げられます。ただし、これらの代替...
ε-白藜芦醇脱氢二聚体の代替品はありますか?
ε-白藜芦醇脱氢二聚体の代替品としては、ε-白藜芦醇、ポリフェノール類、フラボノイド類が挙げられます。これらは類似の化学構造と生物学的活性を持っています。ただし...
掲載誌
Analyst

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.














