On-line atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry
文献情報
Jürg M. Daniel, Sille Ehala, Sebastian D. Friess, Renato Zenobi
A new technique is presented for the coupling of atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) mass spectrometry with liquid delivery systems. Mass measurements of polymers and peptides are demonstrated using a co-dissolved matrix, e.g. α-cyano-4-hydroxycinnamic acid (HCCA). Improvements in terms of sensitivity are achieved by optimizing the shape und control of the exit capillary and by using a laser (355 nm) at a 1 kHz repetition rate. Two calibration experiments promise a good applicability of the presented coupling method for quantitative measurements. The limit of detection achieved so far is 500 nM for peptides in methanol solution containing 25 mM HCCA.
関連文献
Asymmetric dual species copper(ii/i) electrolyte dye-sensitized solar cells with 35.6% efficiency under indoor light
Renjith S. Pillai, Frédéric Sauvage, Anders Hagfeldt
DOI: 10.1039/D3TA06046B
Low band gap semiconducting covalent organic framework films with enhanced photocatalytic hydrogen evolution
Hüseyin Küçükkeçeci, Rajendra Prasad Paitandi, Vincent Weigelt, Veit Dippold, Shu Seki, Arne Thomas
DOI: 10.1039/D3TA04552H
Fast redox conversion in lithium–sulfur batteries enabled by Cu-doped W18O49 with abundant oxygen defects
Guojun Dong, Yanfei Yang
DOI: 10.1039/D3TA05773A
A new selection criterion for voltage windows of aqueous zinc ion hybrid capacitors: achieving a balance between energy density and cycle stability
Fanda Zeng, Xiliang Gong, Zijin Xu, Zhengyan Du, Jian Xu, Ting Deng, Dong Wang, Yi Zeng, Shansheng Yu, Zeshuo Meng, Xiaoying Hu, Hongwei Tian
DOI: 10.1039/D3TA05838G
Two-dimensional metal–organic polymers as cathode hybrid materials for high-performance Al-batteries
Verónica Montes-García, Adam Gorczyński, Michał Bielejewski, Andrzej Musiał, Ignacio Pérez-Juste, Paolo Samorì
DOI: 10.1039/D3TA05730E
Correction: Achieving highly efficient CO2 to CO electroreduction exceeding 300 mA cm−2 with single-atom nickel electrocatalysts
Hui-Yun Jeong, Mani Balamurugan, Eun-suk Jeong, Uk Sim
DOI: 10.1039/D3TA90261G
Direct measurement of the hydrogen adsorption entropy on shape-controlled Pt nanoparticles using electrochemical microcalorimetry
Luis E. Botello, José Solla-Gullón, Víctor Climent, Juan M. Feliu, Rolf Schuster
DOI: 10.1039/D3TA04937J
Atomic Sn sites on nitrogen-doped carbon as a zincophilic and hydrophobic protection layer for stable Zn anodes
Yijie Wang, Yan Tan, Chuanwei Cheng
DOI: 10.1039/D3TA06372K
こちらもおすすめ
噻奈普汀乙酯の物理化学的性質は何ですか?
CAS番号66981-77-9の噻奈普汀乙酯は、結晶性白色粉末であり、分子量は476.9 g/molです。この化合物は水に溶けにくく、一般的には有機溶媒で溶解し...
アミピシリン不純物Fとは何ですか?
アミピシリン不純物Fは、CAS番号124774-48-7の化合物です。これは、抗生物質アミピシリンの生産過程で生成される不純物の一つであり、(4S)-2-({[...
イリジウム(I)ヘキサフルオロフォスファートの代替品はありますか?
イリジウム(I)ヘキサフルオロフォスファートの代替品として、他の有機金属化合物や非有機金属化合物が使用されることがあります。具体的には、ダイゾニウム塩や他の金属...
含有3-(苯氧基甲基)苯硼酸频那醇酯の廃棄物はどのように処理すべきですか?
含有3-(苯氧基甲基)苯硼酸频那醇酯の廃棄物は、安全な方法で処理する必要があります。まず、廃棄物を適切な容器に収集し、避けて保管します。次に、専門の廃棄処理業者...
2-甲基辛-1-醇を取り扱う際の実験室安全事項は何ですか?
取り扱う際は、密閉のゴーグルと手袋を着用することが推奨されます。ドラフトチャンバーを使用し、漏洩時には速やかに取り扱いを中止し、適切な排気設備を使用してください...
3α-アセトキノイドコレステロールエステルはどのように保存すればよいですか?
3α-アセトキノイドコレステロールエステルは、常温から低温(0-5℃)の暗所で保存し、密閉容器に入れることで安定性を保つことが推奨されます。また、湿気や酸素から...
2-ぶンジロキシ-4-(トリフルオロメチル)フェノルビノン酸の主な用途は何ですか?
2-ぶンジロキシ-4-(トリフルオロメチル)フェノルビノン酸は、化学合成の触媒としての使用や、医薬品の合成材料としての役割があります。また、特定の合成路線で使用...
(2S,3R)-2-氨基-3-甲基丁二酸はどのように合成されますか?
(2S,3R)-2-氨基-3-甲基丁二酸は、2-ヒドロキシ-3-メチル丁酸とアミノ化反応を行うことで合成されます。触媒としてジクロロメタンが使用され、選択性と収...
1-Benzyl-2-phenyl-1H-imidazoleはどのように保存すればよいですか?
この化合物は常温で避けてください。直射日光を避け、密閉容器で保存し、湿気を防水の容器に入れて保管してください。
掲載誌
Analyst

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.














